m+Medelevator.RU
← Поиск публикаций
Talanta · 2014

A new analytical method to determine non-steroidal anti-inflammatory drugs in surface water using in situ derivatization combined with ultrasound-assisted emulsification microextraction followed by gas chromatography-mass spectrometry.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lee Cheong Hoon, Shin Yujin, Nam Min Woo, Jeong Kyung Min, Lee Jeongmi

Аннотация

Because of the high stability and potential toxic effects of non-steroidal anti-inflammatory drugs (NSAIDs), it is important to closely monitor their concentrations in the environment using a sensitive analytical method. In this study, a simple, rapid, efficient, and sensitive analytical method based on gas chromatography-mass spectrometry (GC-MS) was developed to determine the levels of seven common NSAIDs in various types of surface water. To simplify sample preparation, in situ derivatization using methyl chloroformate was combined with ultrasound-assisted emulsification microextraction. For selection and optimization of significant variables, experiments were statistically designed using Plackett-Burman design and central composite design. The resulting optimal conditions for derivatization and extraction were 100 μL of chloroform (extraction solvent), 10.0 mL of sample, and 240 μL of pyridine (catalyst as a base in derivatization). The optimized sample preparation coupled with optimized GC-MS analysis in selected ion monitoring mode provided good linearity from 0.010 to 5.0 ng mL(-1), and a limit of detection between 0.0050 and 0.010 ng mL(-1), good intra-day and inter-day precision (0.30-6.3% and 5.1-9.5%, respectively), and good accuracy (relative recovery; 91-117% at 0.20 ng mL(-1) and 77-105% at 2.5 ng mL(-1)). Compared with previously reported methods, the current method requires a small volume of sample and simple sample preparation steps for sensitive determination of NSAID levels using a conventional GC-MS system. The method was successfully applied to determine the levels of seven common NSAIDs in various types of surface water.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты