Clinical biochemistry · 2015
Quantification of darunavir and etravirine in human peripheral blood mononuclear cells using high performance liquid chromatography tandem mass spectrometry (LC-MS/MS), clinical application in a cohort of 110 HIV-1 infected patients and evidence of a potential drug-drug interaction.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Belkhir Leïla, De Laveleye Morgane, Vandercam Bernard, Zech Francis, Delongie Kevin-Alexandre, Capron Arnaud, Yombi Jean, Vincent Anne, Elens Laure, Haufroid Vincent
Аннотация
OBJECTIVES: To describe the validation of a sensitive high performance liquid chromatography tandem mass spectrometry (LC-MS/MS) method allowing the simultaneous quantification of darunavir (DRV) and etravirine (ETR) in peripheral blood mononuclear cells (PBMCs) and its application in a cohort of HIV-1 infected patients.
METHODS: Blood samples were obtained from 110 patients. PMBCs were isolated using density gradient centrifugation. Drug extraction from PBMCs was performed with a 60:40 methanol-water (MeOH-H2O) solution containing deuterated IS (DRV-d9 and ETR-d8). The chromatographic separation was performed on a RP18 XBridge™ column.
RESULTS: The geometric mean (GM) of cell associated concentration ([DRV]CC) and plasmatic concentration ([DRV]plasma) were 360.5ng/mL (CI95%:294.5-441.2) and 1733ng/mL (CI95%:1486-2021), respectively. A geometric mean intracellular (IC)/plasma ratio (GMR) of 0.21 (CI95%:0.18-0.24) was calculated. Adjusted for dose/body surface area and post-intake time, a statistically significant correlation was observed between [DRV]Plasma and the eGFR (p=0.002) and between [DRV]Plasma and the concomitant use of ETR (p=0.038). For the 10 patients receiving ETR in addition to DRV, the GM of [ETR]Plasma (available for 8 out of 10 patients) and [ETR]CC were 492.3ng/mL and 2951ng/mL respectively. The GMR of ETR was 7.6 (CI95%: 3.61-13.83).
CONCLUSIONS: A handy and sensitive high performance LC-MS/MS method allowing the simultaneous quantification of DRV and ETR in PBMCs has been described and successfully applied in the largest cohort of DRV-treated patients reported to date. ETR accumulates more efficiently in PBMCs compared to DRV. We have also highlighted a possible impact of ETR on DRV plasma concentrations requiring further investigations.
METHODS: Blood samples were obtained from 110 patients. PMBCs were isolated using density gradient centrifugation. Drug extraction from PBMCs was performed with a 60:40 methanol-water (MeOH-H2O) solution containing deuterated IS (DRV-d9 and ETR-d8). The chromatographic separation was performed on a RP18 XBridge™ column.
RESULTS: The geometric mean (GM) of cell associated concentration ([DRV]CC) and plasmatic concentration ([DRV]plasma) were 360.5ng/mL (CI95%:294.5-441.2) and 1733ng/mL (CI95%:1486-2021), respectively. A geometric mean intracellular (IC)/plasma ratio (GMR) of 0.21 (CI95%:0.18-0.24) was calculated. Adjusted for dose/body surface area and post-intake time, a statistically significant correlation was observed between [DRV]Plasma and the eGFR (p=0.002) and between [DRV]Plasma and the concomitant use of ETR (p=0.038). For the 10 patients receiving ETR in addition to DRV, the GM of [ETR]Plasma (available for 8 out of 10 patients) and [ETR]CC were 492.3ng/mL and 2951ng/mL respectively. The GMR of ETR was 7.6 (CI95%: 3.61-13.83).
CONCLUSIONS: A handy and sensitive high performance LC-MS/MS method allowing the simultaneous quantification of DRV and ETR in PBMCs has been described and successfully applied in the largest cohort of DRV-treated patients reported to date. ETR accumulates more efficiently in PBMCs compared to DRV. We have also highlighted a possible impact of ETR on DRV plasma concentrations requiring further investigations.
Предметные рубрики MeSH
BiomarkersChromatography, High Pressure LiquidCohort StudiesDarunavirDrug InteractionsDrug MonitoringFemaleFollow-Up StudiesHIVHIV InfectionsHIV Protease InhibitorsHumansLeukocytes, MononuclearLimit of DetectionMaleMiddle AgedNitrilesPrognosisPyridazinesPyrimidinesReverse Transcriptase InhibitorsTandem Mass Spectrometry