MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jbiomech.2022.111057

Медицинская библиотека · Journal of biomechanics · 2022

A FE study on the effect of interference fit and coefficient of friction on the micromotions and interface gaps of a cementless PEEK femoral component.

Post Corine E, Bitter Thom, Briscoe Adam, Verdonschot Nico, Janssen Dennis

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The use of a more compliant material, such as polyetheretherketone (PEEK), for a cementless femoral component is a potential solution to prevent aseptic loosening caused by peri-prosthetic stress-shielding. Long-term fixation of a cementless femoral component is achieved by a proper primary fixation of the bone-implant interface, which is influenced by the interference fit and frictional properties of the implant surface. This computational study investigates the sensitivity of micromotions and interface gaps of a cementless PEEK femoral component to the interference fit and coefficient of friction. 24 finite element models of the femur and femoral component were created with variations in implant material, interference fit and coefficient of friction. Peak loads of a jogging activity were applied on the models. Micromotions and interface gaps were both sensitive to the interference fit, coefficient of friction and implant material. Besides the implant material, the micromotions and interface gaps of the implant were most sensitive to the interference fit. Compared to the cobalt-chrome (CoCr) femoral component, the PEEK femoral component generated higher micromotions and interface gaps when equal interference fit and friction values were applied. However, increasing the interference fit and friction of the PEEK component resulted in micromotion values comparable with the CoCr component. This result leads to possibilities using cementless PEEK femoral components.

Для цитирования: Post Corine E, Bitter Thom, Briscoe Adam, Verdonschot Nico, Janssen Dennis. A FE study on the effect of interference fit and coefficient of friction on the micromotions and interface gaps of a cementless PEEK femoral component.. Journal of biomechanics. 2022. DOI: 10.1016/j.jbiomech.2022.111057.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.