m+Medelevator.RU
← Поиск публикаций
Annales de cardiologie et d'angeiologie · 2012

[Assessment of antihypertensive monotherapies effectiveness by home blood pressure self-measurement in hypertensive patients].

Сравнительное исследованиеАннотация на английскомСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hanon O, Laroche P, Vidal J-S, Pannier B, Postel-Vinay N, Vaisse B, Girerd X

Аннотация

OBJECTIVE: To evaluate the blood pressure (BP) control and the efficacy of antihypertensive monotherapy using home BP self-measurement in a French population of treated hypertensive subjects in 2007 2009 and 2010.

METHODS: The French League Against Hypertension Surveys (FLAHS) are conducted among a representative sample of individuals aged 35 years and older living in France. For the 2007, 2009 and 2010 surveys, a sample of 1467 subjects who owned a BP self-measurement device and performed three consecutive morning BP measurements were included. Among the 60% of subjects who reported taking at least one antihypertensive drug, we analyzed subjects treated with one of the following antihypertensive monotherapy, i.e., beta-blocker (BB), ACE inhibitors, calcium channel blocker (CCB) and angiotensin receptor blockers (ARB).

RESULTS: Among treated hypertensive subjects (n=886), 66% (n=586) had home BP below the 140/90mmHg threshold and 50% (n=449) below 135/85mmHg. Three hundred two subjects were treated with a single antihypertensive drug, 33% had ARB, 25% BB, 19% CCB and 13% ACE inhibitors. Age (years) for each treatment group is different (P<0.01) CCB (72.1±9.3), BB (65.6±9.8), ARB (68.6±8.9) and ACEI (67.3±10.2). The mean systolic/diastolic BP (mmHg) is not comparable between monotherapy 130.7/76.1 (ARB), 130.7/78.7 (BB), 134.0/75.2 (CCB) and 139.1/80.3 (ACEI) for ARB, BB, CCB and ACE inhibitors respectively. Compared to ACE inhibitors, BP was significantly lower with ARB (P<0.01). The proportion of subjects with a BP below 140/90mmHg was 73% for ARB, 52% for BB, 68% for CCB and 47% for ACE with a statistical significance (P=0.03) for ARB vs. ACEI and CCB vs. ACEI.

CONCLUSION: Among subjects treated for hypertension who owned a BP self-measurement device, 50 to 66% had a controlled BP (depending on the threshold used). It is observed differences between antihypertensive efficacy of monotherapy with a larger number of patients controlled with ARB or CCB.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты