ENHANCED RADIOACTIVE CONTENT OF 'BALANCE' BRACELETS.

Tsroya S, Pelled O, Abraham A, Kravchik T, German U

СтатьяПеревод в очереди

Аннотация

During a routine whole body counting measurement of a worker at the Nuclear Research Center Negev, abnormal activities of (232)Th and (238)U were measured. After a thorough investigation, it was found that the radioactivity was due to a rubber bracelet ('balance bracelet') worn by the worker during the measurement. The bracelet was counted directly by an high pure germanium gamma spectrometry system, and the specific activities determined were 10.80 ± 1.37 Bq g(-1) for (232)Th and 5.68 ± 0.88 Bq g(-1) for natural uranium. These values are obviously high compared with normally occurring radioactive material (NORM) average values. The dose rate to the wrist surface was estimated to be ∼3.9 µGy h(-1) and ∼34 mGy for a whole year. The dose rate at the centre of the wrist was estimated to be ∼2.4 µGy h(-1) and ∼21 mGy for a whole year. The present findings stresses a more general issue, as synthetic rubber and silicone products are common and widely used, but their radioactivity content is mostly uncontrolled, thus causing unjustified exposure due to enhanced NORM radioactivity levels.

Для цитирования: Tsroya S, Pelled O, Abraham A, Kravchik T, German U. ENHANCED RADIOACTIVE CONTENT OF 'BALANCE' BRACELETS.. Radiation protection dosimetry. 2015. DOI: 10.1093/rpd/ncv456.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.