MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/bmc.3221

Медицинская библиотека · Biomedical chromatography : BMC · 2014

Improved protein deproteinization method for the determination of meloxicam in human plasma and application in pharmacokinetic study.

Liew Kai Bin, Loh Gabriel Onn Kit, Tan Yvonne Tze Fung, Peh Kok Khiang

СтатьяПеревод в очереди

Аннотация

A simple, rapid, specific and reliable high-performance liquid chromatographic assay of meloxicam in human plasma has been developed using a C18 reversed-phase analytical column. Reversed-phase chromatography was conducted using a mobile phase of 0.02 potassium dihydrogen phosphate (adjusted to pH 2.7 with phosphoric acid)-acetonitrile-triethylamine (35:65:0.05, v/v) with UV detection at 354 nm. The drug in human plasma was deproteinized using a combination of methanol and chloroform. This method is simple, rapid and consistent with a high recovery of meloxicam in human plasma ranging from 93.29 to 111.09%. Regression analysis for the calibration plot for plasma standards obtained for the drug concentrations between (25-4000) ng/mL indicated excellent linearity (r ≥ 0.9997). The proposed method was applied to study the bioequivalence between Mobic (original) and Melocam (generic) products. The study was conducted on using two tablets (4 × 7.5 mg) of each of the commercial product and the reference standard in a two-way open randomized crossover design involving 20 volunteers. Area under the concentration-time curve, peak concentration (C(max)) and time to reach C(max) were 72,868.61 ng h/mL, 2133.93 ng/mL and 4.06 h for Mobic, and 78,352.52 ng h/mL, 2525.18 ng/mL and 3.61 h for Melocam. Two C(max) were discovered in the pharmacokinetic profiles which confirm enterohepatic recirculation.

Для цитирования: Liew Kai Bin, Loh Gabriel Onn Kit, Tan Yvonne Tze Fung, Peh Kok Khiang. Improved protein deproteinization method for the determination of meloxicam in human plasma and application in pharmacokinetic study.. Biomedical chromatography : BMC. 2014. DOI: 10.1002/bmc.3221.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.