MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.chroma.2014.04.005

Медицинская библиотека · Journal of chromatography. A · 2014

Estrogenic compounds determination in water samples by dispersive liquid-liquid microextraction and micellar electrokinetic chromatography coupled to mass spectrometry.

D'Orazio Giovanni, Asensio-Ramos María, Hernández-Borges Javier, Fanali Salvatore, Rodríguez-Delgado Miguel Ángel

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

In this work, a group of 12 estrogenic compounds, i.e., four natural sexual hormones (estrone, 17β-estradiol, 17α-estradiol and estriol), an exoestrogen (17α-ethynylestradiol), a synthetic stilbene (dienestrol), a mycotoxin (zearalenone) and some of their major metabolites (2-methoxyestradiol, α-zearalanol, β-zearalanol, α-zearalenol and β-zearalenol) have been separated and determined by micellar electrokinetic chromatography (MEKC) coupled to electrospray ion trap mass spectrometry. For this purpose, a background electrolyte containing an aqueous solution of 45 mM of perfluorooctanoic acid (PFOA) adjusted to pH 9.0 with an ammonia solution, as MS friendly surfactant, and methanol (10% (v/v)), as organic modifier, was used. To further increase the sensitivity, normal stacking mode was applied by injecting the sample dissolved in an aqueous solution of 11.5mM of ammonium PFO (APFO) at pH 9.0 containing 10% (v/v) of methanol for 25s. Dispersive liquid-liquid microextraction, using 110 μL of chloroform and 500 μL of acetonitrile as extraction and dispersion solvents, respectively, was employed to extract and preconcentrate the target analytes from different types of environmental water samples (mineral, run-off and wastewater) containing 30% (w/v) NaCl and adjusted to pH 3.0 with 1M HCl. The limits of detection achieved were in the range 0.04-1.10 μg/L. The whole method was validated in terms of linearity, precision, recovery and matrix effect for each type of water, showing determination coefficients higher than 0.992 for matrix-matched calibration and absolute recoveries in the range 43-91%.

Для цитирования: D'Orazio Giovanni, Asensio-Ramos María, Hernández-Borges Javier, Fanali Salvatore, Rodríguez-Delgado Miguel Ángel. Estrogenic compounds determination in water samples by dispersive liquid-liquid microextraction and micellar electrokinetic chromatography coupled to mass spectrometry.. Journal of chromatography. A. 2014. DOI: 10.1016/j.chroma.2014.04.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.