MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0126818

Медицинская библиотека · PloS one · 2015

Quantitative Evaluation of the Substantially Variable Morphology and Function of the Left Atrial Appendage and Its Relation with Adjacent Structures.

Li Cai-Ying, Gao Bu-Lang, Liu Xiao-Wei, Fan Qiong-Ying, Zhang Xue-Jing, Liu Guo-Chao, Yang Hai-Qing, Feng Ping-Yong, Wang Yong, Song Peng

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To investigate quantitatively the morphology, anatomy and function of the left atrial appendage (LAA) and its relation with adjacent structures.

MATERIALS AND

METHODS

A total of 860 patients (533 men, 62.0%, age 55.9±10.4 year) who had cardiac multidetector computed tomography angiography from May to October 2012 were enrolled for analysis.

RESULTS

Seven types and 6 subtypes of LAA morphology were found with Type 2 being the most prevalent. Type 5 was more significantly (P<0.05) present in women (8.0%) than in men (4.2%). LAA orifice was oval in 81.5%, triangular in 7.3%, semicircular in 4%, water drop-like in 3.2%, round in 2.4% and foot-like in 1.6%. The LAA orifice had a significantly greater (P<0.01) major axis in men (24.79±3.81) than in women (22.68±4.07). The LAA orifice long axis was significantly (P<0.05) positively correlated with the height, weight and surface area of the patient. The LAA morphology parameters displayed strong positive correlation with the left atrium volume, aortic cross area long axis or LSPV long axis but poor correlation with the height, weight, surface area and vertebral body height of the patients. Four types of LAA ridge were identified: AI, AII, B and C with the distribution of 17.6%, 69.9%, 5.9% and 6.6%, respectively. The LAA had a significantly (P<0.05) greater distance from its orifice to the mitral ring in women than in men. The LAA had two filling and two emptying processes with the greatest volume at 45% phase but the least volume at 5% phase. The LAA maximal, minimal and emptying volumes were all significantly (P<0.05) positively correlated with the body height, weight and surface area, whereas the LAA ejection fraction had an inverse correlation with the LAA minimal volume but no correlation with the maximal volume.

CONCLUSION

The LAA has substantially variable morphologies and relation with the adjacent structures, which may be helpful in guiding the LAA trans-catheter occlusion or catheter ablation procedures.

Для цитирования: Li Cai-Ying, Gao Bu-Lang, Liu Xiao-Wei, Fan Qiong-Ying, Zhang Xue-Jing, Liu Guo-Chao, Yang Hai-Qing, Feng Ping-Yong, Wang Yong, Song Peng. Quantitative Evaluation of the Substantially Variable Morphology and Function of the Left Atrial Appendage and Its Relation with Adjacent Structures.. PloS one. 2015. DOI: 10.1371/journal.pone.0126818.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.