The Hypoxia Alarm of a Multigas Analyzer Is Triggered During Helicopter Takeoffs in Helicopter Emergency Medical Services Operations.
Аннотация
OBJECTIVE
Safety in helicopter emergency medical services (HEMS) settings might be enhanced by the routine use of portable multigas analyzers to indicate hypoxic ambient air mixtures and the presence of hazardous gases.
METHODS
In our HEMS (EC-135, Lifeliner 1, Amsterdam, The Netherlands), we introduced a professional multigas analyzer (Gas Alert Max XT II; Honeywell Analytics, Lincolnshire, IL) to prospectively detect possible hazardous gas mixtures. This analyzer measures ambient oxygen percentage (FO2, 0%-30%), carbon monoxide (CO, 0-1,000 ppm), hydrogen sulfide (H2S, 0-200 ppm), and combustibles (lower explosive limit, %).
RESULTS
Before 12 HEMS flights, we measured a stable baseline ambient FO2 of 20.9%. However, in all flights, takeoff to cruising altitude (500-1,000 ft) markedly decreased the measured FO2 to 19.1% ± 0.1% (mean ± standard deviation; Wilcoxon signed rank test, P = .002) with a minimum of 18.8%. This triggered the optoacoustic hypoxia alarm (preset to 19.5% to comply with international guidelines) in all cases. Maintaining cruise altitude restored measured FO2 slowly back to 20.9%. In contrast, CO, H2S, and combustibles remained unchanged during takeoff and flight.
CONCLUSIONS
The hypoxia alarm of multigas analyzers is reproducibly triggered during helicopter takeoff. This observation may be explained by properties of certain multigas analyzers using a capillary controlled concentration sensor for FO2 measurement. Flight crews, increasingly equipped with those multigas analyzers, should be aware of this fact.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.