The longitudinal intraluminal concentration gradient in the perfused rat jejunum and the appropriate mean concentration for calculation of the absorption rate.
Аннотация
In anaesthetized rats, jejunal segments 30 cm in length were perfused (rates:0.1, 0.2,0.5 ml/min) with solutions containing antipyrine, salicylic acid, urea, L-lysine, L- and D-phenylalanine. The intraluminal concentration was determined approx. 10, 20, and 30 cm from the inflow cannula. The intraluminal concentration gradients were almost exponential and corresponded to the gradient predicted for a laminar flow through a solute-permeable circular tube. This gradient has a slightly greater curvature than the exponential one. Theoretical considerations showed that the logarithmic mean (Co-Cz)/ln(Co/Cz) of the in- and outflow concentration is the best average value for application in non-integrated absorption equations. This is also valid for the temporal concentration gradient after single administration of a substance into an intestinal segment.