MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpba.2012.11.026

Медицинская библиотека · Journal of pharmaceutical and biomedical analysis · 2012

Dispersive liquid-liquid microextraction combined with ultra-high performance liquid chromatography for the simultaneous determination of 25 sulfonamide and quinolone antibiotics in water samples.

Herrera-Herrera Antonio V, Hernández-Borges Javier, Borges-Miquel Teresa M, Rodríguez-Delgado Miguel Ángel

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод в очереди

Аннотация

In this work, a dispersive liquid-liquid microextraction (DLLME) procedure combined with ultra-high performance liquid chromatography with diode-array detection was developed to determine 25 antibiotics in mineral and run-off waters. Optimum DLLME conditions (5 mL of water at pH=7.6, 20% (w/v) NaCl, 685 μL of CHCl₃ as extractant solvent, and 1250 μL of ACN as disperser solvent) allowed the repeatable, accurate and selective determination of 11 sulfonamides (sulfanilamide, sulfacetamide, sulfadiazine, sulfathiazole, sulfadimidin, sulfamethoxypyridazine, sulfadoxine, sulfamethoxazole, sulfisoxazole, sulfadimethoxine and sulfaquinoxaline) and 14 quinolones (pipemidic acid, marbofloxacin, fleroxacin, levofloxacin, pefloxacin, ciprofloxacin, lomefloxacin, danofloxacin, enrofloxacin, sarafloxacin, difloxacin, moxifloxacin, oxolinic acid and flumequine). The method was validated by means of the obtention of calibration curves of the whole method as well as a recovery study at two levels of concentration. The LODs of the method were in the range 0.35-10.5 μg/L with recoveries between 78% and 117%.

Для цитирования: Herrera-Herrera Antonio V, Hernández-Borges Javier, Borges-Miquel Teresa M, Rodríguez-Delgado Miguel Ángel. Dispersive liquid-liquid microextraction combined with ultra-high performance liquid chromatography for the simultaneous determination of 25 sulfonamide and quinolone antibiotics in water samples.. Journal of pharmaceutical and biomedical analysis. 2012. DOI: 10.1016/j.jpba.2012.11.026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.