Zhonghua lao dong wei sheng zhi ye bing za zhi = Zhonghua laodong weisheng zhiyebing zazhi = Chinese journal of industrial hygiene and occupational diseases · 2006
[Determination of cotinine in human urine with gas chromatograph-mass spectrometry].
Аннотация на английскомСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Cao Min, Zhang Yi-lun, Jiang Chao-qiang, Lam Tai-hing, Cheng Kar-keung, Zhang Wei-sen
Аннотация
OBJECTIVE: To establish the method of gas chromatograph-mass spectrometry (GC-MS) for the determination of the cotinine (COT) in human urine.
METHODS: The conjugated trans-3'-hydroxycotinine (THOC) and COT were hydrolyzed in human urine with beta-glucuronidase. The composition of COT was extracted with the mixture of dichloromethane and n-butyl acetate (2:1) and was separated with HP-5MS fused-silica capillary column. The GC-MS was used for determining its content.
RESULTS: The monitoring limit of this method was 0.02 microg/L. Its recovery rate was higher than 90%, Its accuracy rate was 4.30%. It was used for the determination of the cotinine in human urine in Guangzhou Biological Bank the Elderly Cohort.
CONCLUSION: The GC-MS method is a good microanalysis for monitoring the cotinine in human urine rapidly and accurately with little background disturbance. It has been applied in our Guangzhou Cohort Study for determining cotinine in human urine.
METHODS: The conjugated trans-3'-hydroxycotinine (THOC) and COT were hydrolyzed in human urine with beta-glucuronidase. The composition of COT was extracted with the mixture of dichloromethane and n-butyl acetate (2:1) and was separated with HP-5MS fused-silica capillary column. The GC-MS was used for determining its content.
RESULTS: The monitoring limit of this method was 0.02 microg/L. Its recovery rate was higher than 90%, Its accuracy rate was 4.30%. It was used for the determination of the cotinine in human urine in Guangzhou Biological Bank the Elderly Cohort.
CONCLUSION: The GC-MS method is a good microanalysis for monitoring the cotinine in human urine rapidly and accurately with little background disturbance. It has been applied in our Guangzhou Cohort Study for determining cotinine in human urine.