Zhongguo Zhong yao za zhi = Zhongguo zhongyao zazhi = China journal of Chinese materia medica · 2005
[Identification of triacylglycerols in coix oil by high performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry].
Аннотация на английскомСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Xiang Zhi-Min, Zhu Ming, Chen Bi-Lian, Chen Yong
Аннотация
OBJECTIVE: To identify triacylglycerols in coix oil.
METHOD: High performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry was used for identification. The experiment was operated under the conditions: spray voltage at 3 000 V, capillary temperature at 250 degrees C, APCI vaporizer temperature at 400 degrees C, and corona current of 4 microA. Sheath gas pressure (high purity liquid nitrogen) was 35 kPa. Mass spectra were obtained over the m/e range of 300 to 900 amu, scan duration of 1s and Q1 peak width at 0.7. The stationary phase was Zorbax Extend C18 column (4.6 mm x 250 mm, 5 microm). The mobile phase: dichloromethane-acetonitrile (35:65), flow rate: 1 mL x min(-1); column temperature: 25 degrees C.
RESULT: 12 triacylglycerols were identified by HPLC-MS method.
CONCLUSION: The result can be used to identify the components in a fingerprint chromatogram of coix oil and its related injection product.
METHOD: High performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry was used for identification. The experiment was operated under the conditions: spray voltage at 3 000 V, capillary temperature at 250 degrees C, APCI vaporizer temperature at 400 degrees C, and corona current of 4 microA. Sheath gas pressure (high purity liquid nitrogen) was 35 kPa. Mass spectra were obtained over the m/e range of 300 to 900 amu, scan duration of 1s and Q1 peak width at 0.7. The stationary phase was Zorbax Extend C18 column (4.6 mm x 250 mm, 5 microm). The mobile phase: dichloromethane-acetonitrile (35:65), flow rate: 1 mL x min(-1); column temperature: 25 degrees C.
RESULT: 12 triacylglycerols were identified by HPLC-MS method.
CONCLUSION: The result can be used to identify the components in a fingerprint chromatogram of coix oil and its related injection product.