Periodic extraction of interstitial fluid from the site of subcutaneous insulin infusion for the measurement of glucose: a novel single-port technique for the treatment of type 1 diabetes patients.

Regittnig Werner, Lindpointner Stefan, Korsatko Stefan, Tutkur Dina, Bodenlenz Manfred, Pieber Thomas R

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Treatment of type 1 diabetes patients could be simplified if the site of subcutaneous insulin infusion could also be used for the measurement of glucose. This study aimed to assess the agreement between blood glucose concentrations and glucose levels in the interstitial fluid (ISF) that is extracted from the insulin infusion site during periodic short-term interruptions of continuous subcutaneous insulin infusion (CSII).

SUBJECTS AND

METHODS

A perforated cannula (24 gauge) was inserted into subcutaneous adipose tissue of C-peptide-negative type 1 diabetes subjects (n=13) and used alternately to infuse rapid-acting insulin (100 U/mL) and to extract ISF glucose during a fasting period and after ingestion of a standard oral glucose load (75 g).

RESULTS

Although periodically interrupted for extracting glucose (every hour for approximately 10 min), insulin infusion with the cannula was adequate to achieve euglycemia during fasting and to restore euglycemia after glucose ingestion. Furthermore, the ISF-derived estimates of plasma glucose levels agreed well with plasma glucose concentrations. Correlation coefficient and median absolute relative difference values were found to be 0.95 and 8.0%, respectively. Error grid analysis showed 99.0% of all ISF glucose values within clinically acceptable Zones A and B (83.5% Zone A, 15.5% Zone B).

CONCLUSIONS

Results show that ISF glucose concentrations measured at the insulin infusion site during periodic short-term interruptions of CSII closely reflect blood glucose levels, thus suggesting that glucose monitoring and insulin delivery may be performed alternately at the same tissue site. A single-port device of this type could be used to simplify and improve glucose management in diabetes.

Для цитирования: Regittnig Werner, Lindpointner Stefan, Korsatko Stefan, Tutkur Dina, Bodenlenz Manfred, Pieber Thomas R. Periodic extraction of interstitial fluid from the site of subcutaneous insulin infusion for the measurement of glucose: a novel single-port technique for the treatment of type 1 diabetes patients.. Diabetes technology & therapeutics. 2012. DOI: 10.1089/dia.2012.0173.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.