MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1063/5.0350044

Медицинская библиотека · The Review of scientific instruments · 2026

Miniaturized fiber-optic bolometer with reduced thermal time constant exhibiting first-order thermal dynamics.

Wang Xiaoli, Moeinimaleki Babak, Alshammari Mohammed, Sheng Qiwen, Syed Musaddeque, Lee Seungsup, Dvorak Andrew, Shafer Morgan W, Han Ming

СтатьяПеревод в очереди

Аннотация

Accurate measurement of transient radiation power is critical for plasma diagnostics in magnetic confinement fusion, where rapid radiation events require high temporal resolution and reliable signal reconstruction. Fiber-optic bolometers (FOBs) based on silicon Fabry-Perot interferometry are attractive alternatives to resistive bolometers because of their compact size, electromagnetic-interference immunity, remote sensing capability, and compatibility with high-temperature and high-vacuum environments. However, conventional FOB designs can exhibit slow and non-first-order thermal responses because of sensing-head thermal capacitance and distributed heat transport in the protruding silica fiber stub, often requiring deconvolution to recover transient radiation profiles. Here, we demonstrate a miniaturized FOB fabricated by femtosecond laser micromachining, featuring a ∼20 μm-diameter silicon pillar and a ∼150 μm-diameter gold absorber disk. The reduced absorber and pillar dimensions decrease sensing-head thermal capacitance, while a flush fiber-copper-holder configuration eliminates the protruding fiber stub and suppresses distributed fiber thermal modes. Compared with previously reported FOBs, the device reduces the cooling time constant from ∼200 to ∼27.5 ms in vacuum while preserving a responsivity of ∼7.8 mK/(W/m2) and a noise-equivalent power density of ∼0.28 W/m2. The thermal response is experimentally shown to be well approximated by a first-order lumped model, enabling direct reconstruction of incident power density using the bolometer equation. Square-wave and millisecond-scale Gaussian radiation transients reconstructed without deconvolution show close agreement with independently measured reference signals, demonstrating ∼1 ms temporal resolution for real-time radiation diagnostics in fusion plasmas.

Для цитирования: Wang Xiaoli, Moeinimaleki Babak, Alshammari Mohammed, Sheng Qiwen, Syed Musaddeque, Lee Seungsup, Dvorak Andrew, Shafer Morgan W, Han Ming. Miniaturized fiber-optic bolometer with reduced thermal time constant exhibiting first-order thermal dynamics.. The Review of scientific instruments. 2026. DOI: 10.1063/5.0350044.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.