m+Medelevator.RU
← Поиск публикаций
Clinical chemistry and laboratory medicine · 2026

Validation of synthetic M-protein materials for external quality assessment: homogeneity, commutability, and stability.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bioch Moniek M, Rispens Theo, de Kat Angelino Corrie M, Ten Haaken-Meijer Anke J, van Berkel Miranda, Thelen Marc H M, Jacobs Joannes F M

Аннотация

OBJECTIVES: Accurate quantification of M-proteins is important for clinical management of monoclonal gammopathies. Reliable assessment of trueness on M-protein quantification in External Quality Assessment (EQA) schemes is difficult due to the lack of reference methods and materials for target value assignment. We propose a strategy to produce targeted synthetic M-protein EQA materials by spiking known amounts of human(ised) therapeutic monoclonal antibodies (t-mAb) into null serum. This paper validates homogeneity, commutability, and stability of these materials.

METHODS: Homogeneity was assessed on two aliquoted synthetic M-protein EQA materials comparing within-vial variation with between-vial variation for sodium, total protein, IgG and M-protein quantification. Commutability was assessed by comparing between-method differences in 51 patient-derived and nine synthetic M-protein EQA materials among various M-protein quantification methods. Stability was checked by reanalysis of two previously distributed synthetic M-protein EQA materials.

RESULTS: Within- and between-vial variation were similar in both samples, and therefore homogeneity criteria were met. Commutability was observed for eight out of nine samples, whereas one hypergammaglobulinemic sample was non-commutable. Long-term storage stability at -80 °C was found acceptable in both samples.

CONCLUSIONS: Due to their proven homogeneity, commutability, and stability, targeted synthetic M-protein EQA materials are suitable for use in M-protein EQA schemes. This allows for the assessment of laboratory performances based on target values, and opens the way for harmonisation and exchangeability of M-protein diagnostic methods. Additionally, it provides a new source for the production of M-protein EQA materials, alleviating the demand for large volumes of patient material needed to organise M-protein EQA schemes.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты