m+Medelevator.RU
← Поиск публикаций
Polymers · 2026

Batch-to-Flow Translation of β-Cyclodextrin Polymer Adsorption for Emerging Contaminant Removal: Hydrodynamic and Operational Validation.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Cegarra Antonio Tomás Hernández, Gómez-Morte Teresa, Pellicer José Antonio, Rodríguez-López María Isabel, Vela Nuria, Gil-Izquierdo Ángel, Núñez-Delicado Estrella, Gabaldón José Antonio

Аннотация

Translating adsorption performance from batch experiments to continuous-flow operation is a key step toward practical water-treatment applications. In this study, a laboratory-scale continuous adsorption system based on a water-insoluble β-cyclodextrin-epichlorohydrin (β-CD-EPI) polymer was validated from hydrodynamic, adsorptive, and operational perspectives. Downflow operation caused progressive bed compaction and excessive pressure development, whereas a 90 mm column operated in upflow mobile-bed mode, with visually observed bed expansion, showed comparatively stable pressure-drop behavior at superficial linear velocities below approximately 12 m h-1. Under these controlled high-loading conditions, removal was strongly contaminant-dependent: cyproconazole exceeded 90%, acetaminophen reached 72-77%, hydrochlorothiazide reached 40-65%, ciprofloxacin reached 24-50%, and furosemide remained below 30%. The relative performance for furosemide and hydrochlorothiazide differed from that predicted by previous batch-derived adsorption parameters, demonstrating that batch results cannot be directly extrapolated to dynamic operation. Competitive adsorption in binary and ternary mixtures reduced contaminant removal, while cyproconazole removal decreased from >90% in tap water to 48-55% in secondary-treated wastewater, demonstrating the relevance of the aqueous matrix under the tested continuous-flow conditions. Operational screening tests showed that desorption with 220 mM acetate buffer at pH 4.0 recovered >80% of the retained cyproconazole within 10 min in the tested sequence, followed by a two-stage rinse that restored the operational pH. These preliminary conditions require confirmation through replicated adsorption-desorption cycles under continuous-flow operation. These results identify laboratory-scale hydrodynamic, adsorption, matrix, and regeneration considerations that require confirmation through fixed-condition, long-term testing during subsequent process development.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты