Preclinical Evaluation of the WAVE-track Aspiration Catheter: Safety and Efficacy in the Swine Thrombectomy Model.

Yang Biao, Li Ziao, Wu Yongqiang, Li Ren, Li Peize, Chen Yang, Zhou Zixuan, Wang Xiaogang, Guo Xiaolong, Zhang Huidong, Zhao Yuanli, Guo Geng

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

RATIONALE AND

OBJECTIVES

We investigated the safety and effectiveness of the WAVE-track from the perspectives of imaging and pathology with a swine thrombectomy model to provide a basis for its clinical application, using the ACE aspiration catheter as the control group.

MATERIALS AND

METHODS

In a swine model, various types of thrombi were prepared and placed in the maxillary artery, ascending pharyngeal artery, lingual artery, and renal artery. The WAVE-track group was considered to be the study group, and the ACE aspiration catheter was used as the control group. Thrombectomy with the ADAPT technique or/and repeatedly pushed and withdrawn with aspiration were performed in two groups. The swine were sacrificed on the day of completion of procedure or at 30 ±5 days.

RESULTS

According to the angiographic analysis, although the study group showed a better trend in mTICI distribution, no significant differences were recorded in the recanalization rates between the study group and the control group (mTICI≥2b: WAVE-track group 96.15% vs. ACE group 84.37%). Furthermore, the first-pass effect rates were similar in both groups (WAVE-track group 48.08% vs. ACE group 40.63%). Procedural safety was confirmed in both groups and pathological analysis revealed no clinically significant abnormalities in the two groups. In the subgroup analysis of single-pass and multiple-pass, there were no clinically significant differences found between the two pass types in angiographic and pathology assessment.

CONCLUSION

Compared to the ACE catheter, the WAVE-track aspiration catheter demonstrated high thrombectomy efficacy and safety in a swine model. Additionally, the WAVE-track aspiration catheter demonstrated a favorable safety profile even after multiple thrombectomy passes, with no clinically significant increase in vascular injury compared to single pass.

Для цитирования: Yang Biao, Li Ziao, Wu Yongqiang, Li Ren, Li Peize, Chen Yang, Zhou Zixuan, Wang Xiaogang, Guo Xiaolong, Zhang Huidong, Zhao Yuanli, Guo Geng. Preclinical Evaluation of the WAVE-track Aspiration Catheter: Safety and Efficacy in the Swine Thrombectomy Model.. Academic radiology. 2026. DOI: 10.1016/j.acra.2026.01.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.