The challenging right inferior pulmonary vein: A systematic approach for successful cryoballoon ablation.

Martins Raphaël P, Nicolas Amélie, Galand Vincent, Pichard Camille, Behar Nathalie, Chérel Céline, Daubert Jean-Claude, Mabo Philippe, Leclercq Christophe, Lederlin Mathieu, Pavin Dominique

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Pulmonary vein isolation (PVI) using cryoballoon ablation is widely used for rhythm control in patients with paroxysmal atrial fibrillation. This technique has a steep learning curve, and PVI can be achieved quickly in most patients. However, the right inferior pulmonary vein (RIPV) is often challenging to occlude and isolate.

AIM: We aimed to analyse the efficacy of RIPV ablation using a systematic approach.

METHODS

Consecutive patients referred for cryoballoon ablation of paroxysmal atrial fibrillation were enrolled prospectively. A systematic approach was used for RIPV cryoablation. The primary endpoint was acute RIPV isolation during initial freeze.

RESULTS

A total of 214 patients were included. RIPV isolation during initial freeze occurred in 179 patients (82.2%). Real-time PVI could be observed in 72 patients (33.6%), whereas cryoballoon stability required pushing the Achieve™ catheter inside the RIPVs in the remaining patients. The rate of unsuccessful or aborted first freeze as a result of insufficient minimal temperature was significantly higher in patients with real-time pulmonary vein potential recording (16.7% vs. 6.3%; P=0.031). To overcome this issue and obtain both stability and real-time PVI, a dedicated "whip technique" was developed. Twelve patients (5.6%) required a redo ablation; only two of these had a reconnected RIPV.

CONCLUSIONS

A systematic approach to RIPV cryoablation can lead to a high rate of first freeze application. Operators should not struggle to visualize pulmonary vein potentials before ablation, as this may decrease cryoapplication efficacy. Thus, stability should be preferred over real-time PVI for RIPV ablation. Both stability and real-time PVI can be obtained using a "whip technique".

Для цитирования: Martins Raphaël P, Nicolas Amélie, Galand Vincent, Pichard Camille, Behar Nathalie, Chérel Céline, Daubert Jean-Claude, Mabo Philippe, Leclercq Christophe, Lederlin Mathieu, Pavin Dominique. The challenging right inferior pulmonary vein: A systematic approach for successful cryoballoon ablation.. Archives of cardiovascular diseases. 2019. DOI: 10.1016/j.acvd.2019.05.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.