JSLS : Journal of the Society of Laparoendoscopic Surgeons · 2011
Removal of an intraperitoneal foreign body using a single port laparoscopic procedure.
Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lupascu Cristian, Dabija Marius, Ursulescu Corina, Andronic Dan, Vasiluta Ciprian, Ursaru Manuela
Аннотация
BACKGROUND AND OBJECTIVES: To remove a foreign body from the peritoneal cavity in laparoscopic surgery, 2 or 3 ports are usually used. We have recently performed such a removal using a single 10-mm transumbilical port, a 0-degree laparoscope, a Farabeuf retractor, and a laparoscopic grasping forceps.
METHODS: Two patients with ventriculoperitoneal shunt catheter (V-P shunt) were admitted to our unit during the last year. They previously had a shunt catheter implanted for hydrocephalus of unknown cause. The complete migration of the ventriculoperitoneal shunt catheter into the peritoneal cavity was observed in these patients 12 and 7 years after the implantation. The laparoscopic removal of the migrated catheter was decided on. Its presence and location were confirmed by the use of a 0-degree laparoscope, through a 10-mm trocar port. The catheter was held and pulled out using a grasping forceps that was pushed in just beside the trocar port.
CONCLUSION: The laparoscopic approach enables safe removal of a foreign body in the peritoneal cavity. The procedure can be performed using a single port.
METHODS: Two patients with ventriculoperitoneal shunt catheter (V-P shunt) were admitted to our unit during the last year. They previously had a shunt catheter implanted for hydrocephalus of unknown cause. The complete migration of the ventriculoperitoneal shunt catheter into the peritoneal cavity was observed in these patients 12 and 7 years after the implantation. The laparoscopic removal of the migrated catheter was decided on. Its presence and location were confirmed by the use of a 0-degree laparoscope, through a 10-mm trocar port. The catheter was held and pulled out using a grasping forceps that was pushed in just beside the trocar port.
CONCLUSION: The laparoscopic approach enables safe removal of a foreign body in the peritoneal cavity. The procedure can be performed using a single port.