BACKGROUND

Although burr entrapment is a rare complication of the Rotablator, it is extremely difficult to retrieve a fixedly entrapped burr without surgical procedure.

CASE REPORT: An 84-year-old male with effort angina had heavily calcified coronary trees as well as severe stenosis in the mid LCx, and moderate stenosis in the proximal LCx, and in the LMT. We planned to perform rotational atherectomy in the LCx lesions. Using 7 Fr Q-curve guiding catheter and Rotawire floppy, we began to ablate using 1.5-mm burr at 200,000 rpm. Because the burr could not pass the proximal stenosis, we exchanged the wire for Rotawire extrasupport and the burr for 1.25-mm burr, and restarted the ablation at 220,000 rpm. Although the burr could manage to pass the proximal stenosis, it had become trapped in the mid LCx lesion. Simple pull on the Rotablator, rotation of the burr, and crossing the Conquest (Confianza) wire could not retrieve it. Thus, we cut off the drive shaft and sheath of the Rotablator, inserted 5 Fr 120-cm straight guiding catheter (Heartrail ST01; Terumo) through the remaining Rotablator system, pushed the catheter tip to the lesion around the burr as well as simultaneously pulled the Rotablator, and finally could retrieve it. Then we implanted stents in the LCx and in the LMT without difficulty.

CONCLUSIONS

The 5 Fr straight guiding catheter might be useful for retrieving an entrapped burr (1.25-mm burr).

Для цитирования: Kimura Masayoshi, Shiraishi Jun, Kohno Yoshio. Successful retrieval of an entrapped Rotablator burr using 5 Fr guiding catheter.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2011. DOI: 10.1002/ccd.22995.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.