MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.20903

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2006

The "pull-push" technique to deal with a redundant eustachian valve interfering with placement of a PFO occluder.

Butera Gianfranco, Montinaro Antonio, Carminati Mario

Клинический случайСтатьяПеревод в очереди

Аннотация

OBJECTIVES

To evaluate the role of a new technique to deal with a redundant Eustachian valve (EV) interfering with placement of a patent foramen ovale (PFO) occluder.

BACKGROUND

The EV is a remnant of the embryonic valve of the sinus venosus. In rare occasions, it is large and redundant and it may interfere with catheters and devices used in cardiac catheterization.

METHODS

We have developed a new technique to control the EV in order to avoid interferences with the device for closure of atrial septal defects and PFO's. This technique is called "pull-push" technique and consists in pulling down on the inferior vena cava the redundant EV by using a 6 Fr pigtail catheter while a second operator pushes the right atrial disc out of the long sheath.

RESULTS

Here, we report on two patients with a patent foramen ovale, in whom the EV prevented the right atrial disc of an Amplatzer PFO occluder to be completely flat against the interatrial septum. Finally, we used this technique in one more patient to avoid any interference of a very redundant EV during placement of a Starflex device.

CONCLUSIONS

In conclusion. the so called "pull-push" technique is an alternative and easy technique to control the EV in order to avoid interferences with the device for closure of atrial septal defects and PFO's

Для цитирования: Butera Gianfranco, Montinaro Antonio, Carminati Mario. The "pull-push" technique to deal with a redundant eustachian valve interfering with placement of a PFO occluder.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2006. DOI: 10.1002/ccd.20903.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.