A study on the effect of lead on event-related potentials among lead-exposed workers.

Hirata Mamoru, Kosaka Hiroshi, Yoshida Toshiaki

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

In order to clarify the effect of lead on higher cerebral functions, lead-exposed workers (Pb group) and controls were examined for event-related potentials.

SUBJECTS AND

METHODS

Fourteen lead-exposed workers with a mean age of 57.1 yr (SD=4.27, range 48-64; lead concentration of whole blood ranged from 33 to 106 microg/dl with a mean of 58.6 and SD 28.6 microg/dl) and 19 age-matched control workers with a mean age of 57.3 yr (SD=4.80, range 48-65) were examined. Visual P300 was recorded by button pushing to the target image (minute checkerboard pattern, 20%), and the NO-GO potential by no button pushing to the target image (same as above, 50%).

RESULTS

Latencies of P300 in the Pb group (475+/-46.0 ms) were significantly delayed compared with those in controls (407+/-42.4 ms, p<0.01 by Student's t test). Amplitudes of the NO-GO potential in the Pb group (4.59+/-2.04 microV) significantly increased compared with those in the controls (3.18+/-1.41 microV, p<0.05).

CONCLUSION

The finding suggests that lead exposure affects high cerebral functions of cognition and attention, but is unclear in suppression of movement.

Для цитирования: Hirata Mamoru, Kosaka Hiroshi, Yoshida Toshiaki. A study on the effect of lead on event-related potentials among lead-exposed workers.. Industrial health. 2004. DOI: 10.2486/indhealth.42.431.