Pseudoaccommodation: BioComFold versus a foldable silicone intraocular lens.

Legeais J M, Werner L, Werner L, Abenhaim A, Renard G

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To assess the degree of pseudoaccommodation amplitude correlated with shifts along the anteroposterior axis of the BioComFold foldable intraocular lens (IOL).

SETTING

Department of Ophthalmology, Hôtel-Dieu Hospital, Paris, France.

METHODS

This prospective study comprised 30 eyes of 30 patients operated on consecutively for cataract by phacoemulsification and in-the-bag implantation of a BioComFold (15 patients) or a foldable control (15 patients) IOL. The BioComFold IOL has a peripheral bulging ring that pushes the optic forward during the effort to accommodate, creating a zoom effect. Pseudoaccommodation amplitude was evaluated using the blurring of controlled vision by adding spheres, with the best correction for distance vision in place. Pupil diameter was measured with a Goldmann campimeter under constant illumination. Anterior chamber depth was determined by A-scan (Paxial, Biophysic Medical) 30 minutes after cyclopentolate 1% was instilled and again 30 minutes after pilocarpine 2% was instilled.

RESULTS

The difference in pseudoaccommodation amplitude and pupil diameter between the 2 groups was not statistically significant (P = .6737 and P = .4014, respectively). The IOL's forward shifts from maximal ciliary relaxation to maximal ciliary contraction were significantly greater in the BioComFold group (P = .0215).

CONCLUSION

The design of the BioComFold IOL allowed greater forward optic shifts along the anteroposterior axis during the effort to accommodate. Nevertheless, this shift was not correlated with a significantly greater pseudoaccommodation amplitude.

Для цитирования: Legeais J M, Werner L, Werner L, Abenhaim A, Renard G. Pseudoaccommodation: BioComFold versus a foldable silicone intraocular lens.. Journal of cataract and refractive surgery. 1999. DOI: 10.1016/s0886-3350(99)80137-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.