Contraception · 2026
Comparing the TCu380A and a small Nova-T copper IUD: secondary analysis of discontinuation probabilities, bleeding outcomes and satisfaction in nulliparous participants from a 3-year randomized trial.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Hubacher David, Schreiber Courtney A, Turok David K, Teal Stephanie B, Nelson Anita L, Jensen Jeffrey T, Chen Melissa J, Nanda Kavita, White Katharine O, Dayananda Ila, Chen Pai-Lien, Chen Beatrice A, Goldberg Alisa B, Kerns Jennifer L, Dart Clint, Thomas Michael A, Archer David F, Brown Jill E, Castaño Paula M, Burke Anne E, Kaneshiro Bliss, Blithe Diana L
Аннотация
OBJECTIVES: To compare discontinuation rates, satisfaction, and bleeding/pain outcomes over 3 years in a nulliparous population randomized to one of two copper IUDs.
STUDY DESIGN: We performed secondary analyses of the nulliparous population (n = 927) in a US-based, participant-blinded, randomized trial of the NTCu380-Mini (n = 744) and the TCu380A (n = 183). We calculated overall cumulative Kaplan-Meier IUD discontinuation and reason-specific probabilities by year. At nine timepoints over three years, participants summarized IUD satisfaction (highly satisfied, satisfied, dissatisfied, or highly dissatisfied) and last menstrual bleeding patterns; we analyzed responses over time using generalized linear models and estimating equations (computing odds ratios). On first-year diaries, participants also recorded bleeding and menstrual/intermenstrual pain.
RESULTS: Through one and two years, NTCu380-Mini users had lower overall discontinuation probabilities compared to TCu380A users: 24.8% vs. 32.8%, p = 0.03 and 39.6% vs. 48.0%, p = 0.02, respectively. Cumulative three-year rates were 50.1% (NTCu380-Mini) vs. 56.5% (TCu380A), p = 0.06. Through all intervals, NTCu380-Mini users had lower discontinuation rates due to bleeding and/or pain and lower expulsion rates relative to TCu380A users; cumulative three-years rate were 14.5% vs. 26.8%, p < 0.001 and 10.0% vs. 15.1%, p = 0.03, respectively. Participants reported higher satisfaction with the NTCu380-Mini (OR 1.29 [95% CI 1.01-1.64]). In the first year, median number of bleeding/spotting days in a cycle (7.0) did not differ between products, yet some prolonged bleeding outcomes and type of pain showed product differences favoring the NTCu380-Mini.
CONCLUSION: Over 3 years, nulliparous NTCu380-Mini users had lower expulsion and discontinuation rates for bleeding and pain, and they reported higher satisfaction than TCu380A users.
IMPLICATIONS: The NTCu380-Mini demonstrates comparative benefits in nulliparous users, with lower rates of early discontinuation due to pain and bleeding and expulsions. As copper IUDs are the only non-hormonal, long-acting reversible contraceptives available, future development should prioritize optimizing device design to minimize side effects while maintaining high contraceptive efficacy.
STUDY DESIGN: We performed secondary analyses of the nulliparous population (n = 927) in a US-based, participant-blinded, randomized trial of the NTCu380-Mini (n = 744) and the TCu380A (n = 183). We calculated overall cumulative Kaplan-Meier IUD discontinuation and reason-specific probabilities by year. At nine timepoints over three years, participants summarized IUD satisfaction (highly satisfied, satisfied, dissatisfied, or highly dissatisfied) and last menstrual bleeding patterns; we analyzed responses over time using generalized linear models and estimating equations (computing odds ratios). On first-year diaries, participants also recorded bleeding and menstrual/intermenstrual pain.
RESULTS: Through one and two years, NTCu380-Mini users had lower overall discontinuation probabilities compared to TCu380A users: 24.8% vs. 32.8%, p = 0.03 and 39.6% vs. 48.0%, p = 0.02, respectively. Cumulative three-year rates were 50.1% (NTCu380-Mini) vs. 56.5% (TCu380A), p = 0.06. Through all intervals, NTCu380-Mini users had lower discontinuation rates due to bleeding and/or pain and lower expulsion rates relative to TCu380A users; cumulative three-years rate were 14.5% vs. 26.8%, p < 0.001 and 10.0% vs. 15.1%, p = 0.03, respectively. Participants reported higher satisfaction with the NTCu380-Mini (OR 1.29 [95% CI 1.01-1.64]). In the first year, median number of bleeding/spotting days in a cycle (7.0) did not differ between products, yet some prolonged bleeding outcomes and type of pain showed product differences favoring the NTCu380-Mini.
CONCLUSION: Over 3 years, nulliparous NTCu380-Mini users had lower expulsion and discontinuation rates for bleeding and pain, and they reported higher satisfaction than TCu380A users.
IMPLICATIONS: The NTCu380-Mini demonstrates comparative benefits in nulliparous users, with lower rates of early discontinuation due to pain and bleeding and expulsions. As copper IUDs are the only non-hormonal, long-acting reversible contraceptives available, future development should prioritize optimizing device design to minimize side effects while maintaining high contraceptive efficacy.