m+Medelevator.RU
← Поиск публикаций
Clinical research in cardiology : official journal of the German Cardiac Society · 2026

Aspirated thrombus weight and volume are not associated with improvements in hemodynamics after large-bore mechanical thrombectomy in pulmonary embolism.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Götzinger Felix, Lauder Lucas, Navarro Patricia Perez, Kunz Michael, Wagner Mathias, Tokcan Mert, Boeddinghaus Jasper, Leibundgut Gregor, Böhm Michael, Link Andreas, Scheller Bruno, Mahfoud Felix

Аннотация

BACKGROUND: Large-bore mechanical thrombectomy (LBMT) is a catheter-directed therapy for acute pulmonary embolism (PE). The relationship between aspirated thrombus weight and volume with outcomes remains unclear.

AIMS: The aim was to evaluate the impact of aspirated thrombus weight and volume on outcomes after LBMT.

METHODS: This prospective, open-label, single-arm, single-center registry study included 48 patients undergoing LBMT using the FlowTriever system (Inari Medical/Stryker, Irvine, CA, USA). Thrombus weight and volume were quantified, and clot composition assessed. Associations between thrombus characteristics and clinical, invasive hemodynamics, echocardiographic parameters, and biomarkers were evaluated immediately after the procedure, at hospital discharge, and at 3-month follow-up.

RESULTS: Thrombus material was available in 48 patients (31% women), of which 41 presented with intermediate-risk and 7 with high-risk PE. LBMT resulted in significant reductions in systolic pulmonary artery pressures (sPAP) intraprocedurally (- 12.8 ± 8.3 mmHg, p < 0.001), with a further invasively measured decrease through 3 months (- 9.6 ± 10.6 mmHg, p < 0.001). From baseline to discharge, right ventricular coupling improved (+ 0.24, p < 0.001) and right ventricle (RV)/left ventricle (LV) ratio decreased (- 0.23, p < 0.001). NT-proBNP and high-sensitivity cardiac troponin T declined significantly. Neither thrombus weight nor volume correlated with acute changes in sPAP (ρvolume = 0.06; ρweight = 0.10), RV-uncoupling (ρvolume = 0.47; ρweight = 0.46), and RV/LV ratio (ρvolume = - 0.02; ρweight = - 0.005) (p for all > 0.05), nor with outcomes at 3 months.

CONCLUSIONS: Aspirated thrombus weight and volume were not associated with improvements after LBMT, suggesting that, beyond mechanical obstruction, additional mechanisms potentially including paracrine and endocrine effects of thrombus material may contribute to acute and chronic PE-related cardiopulmonary dysfunction.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты