Feasibility of using a novel optically filtered monochromatic portable X-ray fluorescence (MXRF) to quantify lead in wild bird bones.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Adesina Kolawole E, DiNatale James A, Costa Stephanie S, Faber Bethany, Katzner Todd E, Cooper Sunny, Dean Kristin, Martin Michael, Jackson Brian P, Grier Thomas R, Specht Aaron J

Аннотация

Lead (Pb) threatens wildlife and humans through neurological, cardiovascular, and renal damage. Conventional tissue Pb assessment relies on costly wet-lab methods such as inductively coupled plasma mass spectrometry (ICP-MS). Monochromatic X-ray fluorescence (MXRF) enables rapid, non-destructive, field-deployable Pb detection with lower detection limits than prior portable XRF systems. We evaluated the feasibility, calibration, attenuation correction, and ICP-MS agreement of a doubly curved crystal (DCC)-enhanced MXRF (X-ray Optical Systems, East Greenbush, NY) for bone Pb quantification in American black vultures (Coragyps atratus). Thirty-eight bird bones were analyzed ex vivo (n = 19 femurs; n = 19 tarsometatarsi[TMT]) using an HD Mobile XRF (1-mm spot; Mo anode; silicon drift detector; 200s). Calibration used Pb-doped plaster phantoms (0-100 ppm) with polymethyl methacrylate soft-tissue equivalents (0-5 mm). Spectra (10.0-13.6 keV) were fit with a Gaussian Pb-peak on a smooth background and Compton sideband normalization. Matched samples were quantified by ICP-MS. Agreement was assessed by ordinary least squares (OLS) regression, Pearson r, Passing-Bablok, intraclass correlation coefficient (ICC; two-way, absolute), reduced major axis (RMA) regression, and Bland-Altman analysis. Detection limits were obtained using blank-and-slope calibration and 30 repeated measurements on two bones. Signal attenuated exponentially, limiting reliable quantification beyond ∼3 mm soft tissue. Calibration was linear (counts vs. ppm: R2 = 0.996; phantom nominal vs. MXRF: R2 = 0.994). MXRF agreed closely with ICP-MS (femur r = 0.959, ICC = 0.933; TMT r = 0.962, ICC = 0.953). Bland-Altman mean biases were small (femur: -1.73 μg/g; TMT: -0.42 μg/g) without proportional bias. Passing-Bablok slopes approached unity (≈0.86-0.96) with small intercepts. Practical DLs were 1.79 μg/g(femur) and 0.80 μg/g(TMT) and are the relevant benchmarks for biological measurement; the calibration-derived instrumental DL of 0.03 μg/g at 200 s is an idealized zero-matrix value. This DCC-based MXRF delivered rapid, non-destructive bone Pb estimates concordant with ICP-MS and low DLs. Attenuation correction and fixed geometry support ex vivo Pb surveillance, carcass triage, and program evaluation in birds, with extension to other species, including humans.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты