MedElevator Войти в исследования
← Поиск публикаций

DOI 10.64898/2026.06.25.734354

Медицинская библиотека · bioRxiv : the preprint server for biology · 2026

Modeling and validation of parallel co-flows layer widths in open-capillary trigger valve systems.

Caira T J, Tokihiro Jodie C, Shaposhnikov Alya, Whitten Jamison M, Su Xiaojing, Shin Albert, Robertson Ingrid H, Nicholson Tristan M, Olanrewaju Ayokunle O, Berthier Erwin, Theberge Ashleigh B, Berthier Jean

СтатьяПрепринтПеревод в очереди

Аннотация

Control of fluids is a hallmark of microfluidic systems and fundamental for the successful application of microfluidic devices. Trigger valves use geometric features to autonomously control the release of fluids in microfluidic devices. Our previous work has adapted geometries used in closed trigger valve systems to enable use in open systems, allowing for open microfluidic devices with up to three trigger valves. Here, we focus on the parallel co-flows produced by sequential release of trigger valves and present a model that predicts their layer widths as a function of the geometric characteristics of the different side channels of each trigger valve. We show layered co-flows with widths as low as 50 microns. Additionally, we expand the use of trigger valves in open microfluidic devices by incorporating 1) varied step heights, 2) devices with up to seven trigger valves, and 3) use of varied fluids and plastics. To validate the implementation and use of these trigger valves in open systems, we have developed a theoretical framework to compare predicted outcomes (i.e., fluid travel distance, velocity, and layering width) with our experimental values. This theoretical work offers applications in various fields, including hydrogel patterning for 3D cell culture, organ-on-a-chip models, at-home sample preparation, and autonomous microfluidic systems for biosensing.

Для цитирования: Caira T J, Tokihiro Jodie C, Shaposhnikov Alya, Whitten Jamison M, Su Xiaojing, Shin Albert, Robertson Ingrid H, Nicholson Tristan M, Olanrewaju Ayokunle O, Berthier Erwin, Theberge Ashleigh B, Berthier Jean. Modeling and validation of parallel co-flows layer widths in open-capillary trigger valve systems.. bioRxiv : the preprint server for biology. 2026. DOI: 10.64898/2026.06.25.734354.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.