m+Medelevator.RU
← Поиск публикаций
Academic radiology · 2026

Comparison of Iterative Metal Artifact Reduction Presets In Ultra-high-resolution Photon-counting CT Angiography of Patients with Total Knee Endoprosthesis.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Huflage Henner, Kunz Andreas Steven, Wech Tobias, Patzer Theresa Sophie, Hartung Viktor, Pannenbecker Pauline, Gruschwitz Philipp, Bestler Caroline, Feldle Philipp, Bley Thorsten Alexander, Grunz Jan-Peter

Аннотация

RATIONALE AND OBJECTIVES: Ultra-high-resolution (UHR) photon-counting CT angiography (PCCTA) has become the reference standard for non-invasive assessment of peripheral artery disease. In the presence of total knee endoprosthesis, however, metal artifacts hamper visualization of the popliteal vasculature. This study investigated the effect of the different iterative metal artifact reduction (IMAR) settings in patients with knee joint replacement.

MATERIALS AND METHODS: Twenty-five patients with knee arthroplasty (74.0 ± 8.5 years; 12 women) undergoing lower extremity UHR-PCCTA between August 2024 and August 2025 were included, yielding 31 lower extremities for analysis. Each dataset was reconstructed without IMAR and with the seven available IMAR presets ("Extremity", "Hip", "Pacemaker", "Lung coils", "Shoulder", "Dental", and "Neuro coils"). Objective image quality was assessed by region-of-interest measurements in the most pronounced hyperdense and hypodense artifacts. Subjective image quality was evaluated by seven radiologists using a forced-choice pairwise comparison tool, totaling 6076 pairwise comparisons.

RESULTS: Compared with non-IMAR datasets (median 4300.1 HU) and the other six IMAR presets (3117.9 - 3377.1 HU), application of IMARDental resulted in the strongest reduction of hyperdense artifacts (932.5 HU; all p<0.001). Similarly, IMARDental (-97.5 HU) provided superior reduction of hypodense artifacts versus datasets reconstructed with the other IMAR presets (-567.9 - -1523.3 HU) and without IMAR (-3319.7 HU; all p≤0.022). Image noise was comparable across all reconstructions (median 10.6 - 11.3 HU; all p>0.05). Subjective evaluation of popliteal artery assessability favored IMARDental with the highest preference probability in pairwise comparison to the other IMAR and non-IMAR data (0.92, 95% confidence interval 0.90-0.93).

CONCLUSION: Despite its misleading name, IMARDental provides the strongest reduction of metal artifacts in UHR-PCCTA of the leg, allowing for the best assessability of the popliteal vasculature in patients with total knee endoprosthesis.