MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/10255842.2026.2701144

Медицинская библиотека · Computer methods in biomechanics and biomedical engineering · 2026

Study on the parametric design and mechanical permeability properties of radially graded biomimetic disordered skeletal scaffolds.

Wei Lirong, Zhang Xujing, Xu Yan, Zhu BoLong, Cai Junke, Zhen Jingwen

СтатьяПеревод в очереди

Аннотация

To address the issues that existing bone scaffolds cannot accurately mimic the gradient disordered structure of natural bone, involve cumbersome design processes, and have complex porosity control, this study derived a gradient recurrence formula and designed a radial gradient structure to replicate the density transition pattern of natural bone. Through generative design by adjusting topological software parameters, a single-parameter control mechanism for prism thickness was established to achieve efficient porosity regulation, and a trabecular-like disordered interconnected pore network was constructed. Simulation results showed that the mechanical strength (4-25 MPa) and permeability (3.86 × 10-8-14.75 × 10-8 m2) of the scaffolds all fall within the physiological range of human bone tissue. At porosity levels of 44.4%-74.1%, the flow field and pressure environment were favorable for mass transfer. Then, using strontium- and magnesium-doped calcium silicate/biphasic calcium phosphate (Sr-Mg-CS/BCP) composite material and stereolithography printing technology, micron-scale scaffolds with precision and performance highly consistent with the design presets were successfully fabricated. The heterogeneous gradient pore biomimetic parametric modeling method proposed in this paper provides a crucial methodological foundation for the structural optimization of biomimetic bone scaffolds.

Для цитирования: Wei Lirong, Zhang Xujing, Xu Yan, Zhu BoLong, Cai Junke, Zhen Jingwen. Study on the parametric design and mechanical permeability properties of radially graded biomimetic disordered skeletal scaffolds.. Computer methods in biomechanics and biomedical engineering. 2026. DOI: 10.1080/10255842.2026.2701144.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.