MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.apradiso.2026.112469

Медицинская библиотека · Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026

Three-dimensional nanofiber integration enhances radiation resistance in protective gloves: Molecular mechanisms and predictive modeling.

Kongwut Ornnicha, Laohhapaiboon Phatsaran

СтатьяПеревод в очереди

Аннотация

Electron beam sterilization in medical and nuclear facilities creates ongoing challenges for protective glove integrity, with frequent failures imposing significant safety risks and operational costs. This study employed a comprehensive multi-technique molecular analysis approach using Electron Paramagnetic Resonance (EPR), Positron Annihilation Lifetime Spectroscopy (PALS), and Small-Angle X-ray Scattering (SAXS) to investigate the performance gap between nanofiber-reinforced woven (NFW) and surface-coated (SC) nitrile gloves subjected to clinically-relevant radiation doses (10-25 kGy). The main finding revealed that NFW gloves achieve 2.5-fold longer service life than SC alternatives through superior molecular-level protection mechanisms. EPR spectroscopy showed SC gloves developed 61 % higher radical concentration than NFW gloves at 25 kGy (8.7 × 1017 vs 5.4 × 1017 spins/g), with NFW exhibiting superior radical stability (62 % retention at 168h versus 43 % for SC gloves). PALS demonstrated NFW's significantly lower Void Expansion Coefficient (0.07 vs 0.41 Å3/kGy), correlating with reduced oxygen diffusion rates (1.4 × 10-9 vs 8.7 × 10-9 cm2/s). SAXS analysis established superior Structural Preservation Quotient for woven architecture (0.81 vs 0.33), reflecting enhanced nanoscale organizational stability. NFW gloves retained 68 % of tensile strength at 25 kGy compared to only 42 % for SC gloves, demonstrating practical performance advantages. Integration of these molecular parameters into a comprehensive Molecular Protection Factor (5.7 vs 2.3) enabled accurate prediction of mechanical performance retention with 92 % correlation across the radiation spectrum. Three-dimensional woven integration provided extended Effective Protection Period of 42 months versus 17 months for surface-concentrated alternatives. The protection mechanism hierarchy demonstrated stress distribution effectiveness as the primary factor (41 % contribution), followed by radical isolation (27 %), void restriction (19 %), and network balance (13 %). Interface engineering and spatial distribution optimization offered superior enhancement potential (215 % calculated improvement) compared to traditional antioxidant approaches (maximum 65 % enhancement), establishing validated molecular-scale design principles for next-generation radiation-resistant protective equipment development.

Для цитирования: Kongwut Ornnicha, Laohhapaiboon Phatsaran. Three-dimensional nanofiber integration enhances radiation resistance in protective gloves: Molecular mechanisms and predictive modeling.. Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine. 2026. DOI: 10.1016/j.apradiso.2026.112469.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.