m+Medelevator.RU
← Поиск публикаций
Journal of photochemistry and photobiology. B, Biology · 2025

Plasmonic photothermal based quick sterilization of surgical tools and pathogen suspensions.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kaur Sarabjot, Kaur Parminder, Attery Shobit, Raka Vrushali, Dadwal Rajneesh, Nandanwar Hemraj, Soni Sanjeev

Аннотация

This study investigates the efficacy of plasmonic photothermal technique for quick sterilization of surgical tools and pathogen suspensions for the elimination of a high load of broad-spectrum pathogens viz. ESKAPE pathogens - Candida albicans (5 × 107 CFU/mL of each pathogen). Here, the contaminated surgical tools and the corresponding pathogens suspension to be sterilized, are irradiated with electromagnetic radiation (Visible-NIR) in the presence of synthesized triangular silver nanoplates leading to localized heat generation through plasmonic photothermal phenomenon. The irradiation source including the sterilization device prototype is developed In-house and is used for the sterilization of reusable surgical tools. The sterilization is achieved at lower temperatures of ∼65-70 °C, at atmospheric pressure within 10 min of total duration. Also, sterility of the nanoplates suspension after a treatment cycle is confirmed for its re-use for multiple subsequent sterilization cycles. The demonstrated sterilization efficacy ∼7.69 Log10 reductions of each pathogen, meets the required sterility assurance level (SAL) norms of 6 Log10 reduction. Further, the mechanism behind sterilization efficacy of plasmonic photothermal technique shows the morphological alterations & membrane lysis along with the combined impact of reactive oxygen species (ROS), which disrupts cellular metabolic pathways within the cells. In-vivo investigation of the use of a surgical blade sterilized through plasmonic photothermal technique, on BALB/C mice, further strengthens the real-time application and safety. Contrary to the antimicrobial studies reported in literature for such phenomenon, as far as we are aware, it is the first reported instance of the sterilization for reusable surgical tools through plasmonic photothermal technique.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты