MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/bioengineering12090924

Медицинская библиотека · Bioengineering (Basel, Switzerland) · 2025

Impact of Disinfection and Sterilization on 3D-Printing Resin Performance for Surgical Guides in Cardiac Ablation Surgery.

Kronenberger Rani, Kazma Rawan, Amirabadi Alireza, Uribe Leire Viana, Talevi Giacomo, Kaya Görkem Eylül, Van den Brande Niko, Abadi Ramak Hossein, Kalteremidou Kalliopi-Artemi, Van Hemelrijck Danny, Baert Kitty, Hauffman Tom, Soete Jeroen, Pannone Luigi, Paparella Andrea Maria, Eltsov Ivan, Chierchia Gian Battista, La Meir Mark, Gharaviri Ali, de Asmundis Carlo

СтатьяПеревод в очереди

Аннотация

Patient-tailored, 3D-printed surgical guides offer significant potential to improve precision and therapeutic efficacy in cardiac ablation surgery. However, reliable post-sterilization material performance presents a critical yet underexplored barrier to clinical adoption. This study investigates how disinfection and sterilization impact the mechanical and thermal properties of photopolymer resins. Specimens from two 3D-printing resins (Bioflex A80 MB™, 3Dresyns; MED625FLX™, Stratasys) were treated with four combinations of disinfection techniques (low-temperature manual cleaning; high-temperature machine washing) and sterilization techniques (H2O2 vs. autoclaving). We assessed post-sterilization properties by mechanical (material integrity, bending tests), thermal (differential scanning calorimetry, thermogravimetric analysis), and viscoelastic (dynamic mechanical analysis) studies. Statistical analysis was performed using one-way ANOVA with Bonferroni post hoc tests (α = 0.05). From this preliminary study, we conclude that MED625FLX maintains integrity and flexibility across all tested disinfection and sterilization methods. Bioflex A80 MB is only suitable for low-temperature disinfection-sterilization, as high-temperature treatments cause surface cracking. Neither resin is appropriate for cryogenic conditions due to the risk of brittleness. Further research into post-sterilization properties is essential to ensure the safety and clinical reliability of these materials in cardiac procedures.

Для цитирования: Kronenberger Rani, Kazma Rawan, Amirabadi Alireza, Uribe Leire Viana, Talevi Giacomo, Kaya Görkem Eylül, Van den Brande Niko, Abadi Ramak Hossein, Kalteremidou Kalliopi-Artemi, Van Hemelrijck Danny, Baert Kitty, Hauffman Tom, Soete Jeroen, Pannone Luigi, Paparella Andrea Maria, Eltsov Ivan, Chierchia Gian Battista, La Meir Mark, Gharaviri Ali, de Asmundis Carlo. Impact of Disinfection and Sterilization on 3D-Printing Resin Performance for Surgical Guides in Cardiac Ablation Surgery.. Bioengineering (Basel, Switzerland). 2025. DOI: 10.3390/bioengineering12090924.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.