m+Medelevator.RU
← Поиск публикаций
Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie · 2026

Comparative evaluation of metal ion release and corrosion resistance of orthodontic archwires in different mouthwashes : From rinse to reactivity.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Aileni Kaladhar Reddy, Ganji Kiran Kumar, Dasari Arun Kumar, Rachala Madhukar Reddy, Alruwaili Mohammad Katib, Alam Mohammed Khursheed

Аннотация

OBJECTIVE: To quantitatively compare nickel and chromium ion release and corrosion resistance of copper-nickel-titanium (Cu-NiTi), stainless steel (SS), and beta-titanium (β-Ti) archwires following immersion in povidone-iodine (Betadine), chlorhexidine, amine fluoride (Amflor) mouthwashes, and distilled water.

MATERIALS AND METHODS: An in vitro study was performed using 60 rectangular archwire specimens (20 each of Cu-NiTi, SS, and β‑Ti), divided into four subgroups according to the immersion medium (chlorhexidine, Betadine, Amflor, distilled water; n = 5 per subgroup). Wires were immersed in each solution at 37 °C for 1.5 h to simulate approximately 3 months of daily mouthwash exposure. Metal ion release was analyzed by atomic absorption spectrophotometer (AAS), while corrosion behavior was assessed using potentiodynamic polarization via a Zive SP1 potentiostat. Two-way analysis of variance (ANOVA) with Tukey's post hoc test was used to determine statistically significant effects of wire and solution type (p < 0.05).

RESULTS: Significant differences were observed among wire and solution types (p < 0.001). β‑Ti wires showed no detectable metal ion release and the lowest corrosion rates. Cu-NiTi and SS wires exhibited measurable nickel release, highest in chlorhexidine (46.91 ppm for Cu-NiTi, 42.93 ppm for SS). Chromium release was exclusive to SS (maximum 23.62 ppm). The corrosion hierarchy was chlorhexidine > Betadine > Amflor > distilled water, with β‑Ti demonstrating superior resistance.

CONCLUSION: Both material composition and mouthwash formulation critically affect corrosion and ion release. β‑Ti exhibits optimal biocompatibility, whereas chlorhexidine significantly accelerates corrosion.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты