OBJECTIVE

To quantitatively compare nickel and chromium ion release and corrosion resistance of copper-nickel-titanium (Cu-NiTi), stainless steel (SS), and beta-titanium (β-Ti) archwires following immersion in povidone-iodine (Betadine), chlorhexidine, amine fluoride (Amflor) mouthwashes, and distilled water.

MATERIALS AND

METHODS

An in vitro study was performed using 60 rectangular archwire specimens (20 each of Cu-NiTi, SS, and β‑Ti), divided into four subgroups according to the immersion medium (chlorhexidine, Betadine, Amflor, distilled water; n = 5 per subgroup). Wires were immersed in each solution at 37 °C for 1.5 h to simulate approximately 3 months of daily mouthwash exposure. Metal ion release was analyzed by atomic absorption spectrophotometer (AAS), while corrosion behavior was assessed using potentiodynamic polarization via a Zive SP1 potentiostat. Two-way analysis of variance (ANOVA) with Tukey's post hoc test was used to determine statistically significant effects of wire and solution type (p < 0.05).

RESULTS

Significant differences were observed among wire and solution types (p < 0.001). β‑Ti wires showed no detectable metal ion release and the lowest corrosion rates. Cu-NiTi and SS wires exhibited measurable nickel release, highest in chlorhexidine (46.91 ppm for Cu-NiTi, 42.93 ppm for SS). Chromium release was exclusive to SS (maximum 23.62 ppm). The corrosion hierarchy was chlorhexidine > Betadine > Amflor > distilled water, with β‑Ti demonstrating superior resistance.

CONCLUSION

Both material composition and mouthwash formulation critically affect corrosion and ion release. β‑Ti exhibits optimal biocompatibility, whereas chlorhexidine significantly accelerates corrosion.

Для цитирования: Aileni Kaladhar Reddy, Ganji Kiran Kumar, Dasari Arun Kumar, Rachala Madhukar Reddy, Alruwaili Mohammad Katib, Alam Mohammed Khursheed. Comparative evaluation of metal ion release and corrosion resistance of orthodontic archwires in different mouthwashes : From rinse to reactivity.. Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie. 2026. DOI: 10.1007/s00056-026-00694-2.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.