m+Medelevator.RU
← Поиск публикаций
Canadian journal of anaesthesia = Journal canadien d'anesthesie · 2025

Failure of neuraxial anesthesia for postpartum tubal ligation: a single-centre retrospective cohort study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Foster Megan, Hudson Kelsey, Ehrig Jessica C, Sharpe Emily E, Hofkamp Michael P

Аннотация

PURPOSE: We aimed to identify the neuraxial anesthesia failure rate of de novo single-injection spinal and combined spinal-epidural anesthesia for postpartum tubal ligation at our hospital along with variables associated with neuraxial anesthesia failure.

METHODS: We conducted a single-centre retrospective cohort study of patients who underwent a postpartum tubal ligation with de novo single-injection spinal or combined spinal-epidural anesthesia from 1 January 2020 to 31 December 2022 at Baylor Scott & White Medical Center-Temple (Temple, TX, USA). We defined neuraxial anesthesia failure as conversion to general anesthesia involving the use of an endotracheal tube or supraglottic airway, administration of intravenous propofol at doses > 10 mg, intravenous fentanyl > 100 µg, or the use of inhaled nitrous oxide.

RESULTS: During the study period, 243 patients underwent postpartum tubal ligation with single-injection spinal or combined spinal-epidural anesthesia, and 28 (11.5%) had neuraxial anesthesia failure. Using a multivariate logistic regression designed to predict neuraxial anesthesia failure using variables of interest, we found that a 5-min increase in time from spinal anesthesia placement to skin incision was associated with neuraxial anesthetic failure (adjusted odds ratio [aOR], 3.10; 95% confidence interval [CI], 2.01 to 4.79; P < 0.001) along with a 5-min increase in time from skin incision to wound closure (aOR 1.35; 95% CI, 1.10 to 1.66; P = 0.004) CONCLUSION: Patients who underwent postpartum tubal ligation under single-injection spinal or combined spinal epidural anesthesia had a neuraxial failure rate of 11.5%. Time from spinal placement to skin incision and time from skin incision to wound closure were independently associated with neuraxial anesthesia failure.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты