MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s25092871

Медицинская библиотека · Sensors (Basel, Switzerland) · 2025

Development and Validation in Porcine and Human Models of a Bioimpedance Spectroscopy System for the Objective Assessment of Kidney Graft Viability.

Naranjo-Hernández David, Reina-Tosina Javier, Roa Laura M, Barbarov-Rostán Gerardo, Calvillo-Arbizu Jorge, Talaminos-Barroso Alejandro, Pérez-Valdivia Miguel Ángel, Medina-López Rafael A

СтатьяПеревод в очереди

Аннотация

This work presents an innovative bioimpedance spectroscopy device, developed as a support tool for decision-making during the evaluation of kidney viability for renal transplantation. Given the increasing demand for organs and the need to optimize donation criteria, the precise and objective assessment of renal graft functionality has become crucial. The device, based on a modular design and adapted to the surgical environment, uses a novel Cole model with a frequency-dependent membrane capacitance, which improves measurement accuracy and repeatability compared to conventional models. Adapting the device for operating room usege involved overcoming significant challenges, such as the need for sterilization and a visual, tactile and acoustic user interface that facilitates device usability. Optimizing the sensing stage has minimized the influence of measurement artifacts, which is crucial for obtaining accurate and representative measurements of renal tissue bioelectrical properties. In addition, a rigorous electrode sterilization protocol was designed, ensuring asepsis during the procedure. The results of tests on porcine renal models demonstrated the device's ability to monitor pathophysiological changes associated with renal ischemia, with a notable improvement against measurement repeatability.

Для цитирования: Naranjo-Hernández David, Reina-Tosina Javier, Roa Laura M, Barbarov-Rostán Gerardo, Calvillo-Arbizu Jorge, Talaminos-Barroso Alejandro, Pérez-Valdivia Miguel Ángel, Medina-López Rafael A. Development and Validation in Porcine and Human Models of a Bioimpedance Spectroscopy System for the Objective Assessment of Kidney Graft Viability.. Sensors (Basel, Switzerland). 2025. DOI: 10.3390/s25092871.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.