m+Medelevator.RU
← Поиск публикаций
Antibiotics (Basel, Switzerland) · 2024

Enhanced Effect of Patient Room Disinfection Against Carbapenem-Resistant Enterobacter cloacae and Methicillin-Resistant Staphylococcus aureus Using UV-C Irradiation in Conjunction with UV-C Containment Unit.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kitaya Shiori, Takei Kentarou, Honda Yoshitomo, Kakuta Risako, Kanamori Hajime

Аннотация

Background/Objectives: In environments with high-frequency contact surfaces, drug-resistant bacteria, such as carbapenem-resistant Enterobacterales and methicillin-resistant Staphylococcus aureus (MRSA), can survive for extended periods, contributing to healthcare-associated infections. Ultraviolet (UV)-C irradiation often fails to adequately disinfect shadowed areas, leading to a persistent contamination risk. We evaluated the effectiveness of using a UV-C containment unit (UVCCU) in conjunction with UV-C irradiation to improve the sterilization effects on both direct and indirect surfaces, including shadowed areas, and to assess the leakage of UV radiation to the surroundings. Methods: In a model patient room, agar media inoculated with carbapenem-resistant Enterobacter cloacae and MRSA were placed at multiple locations on direct and indirect surfaces around the bed. We used the UV-C irradiation system, UVDI-360, to irradiate the bedroom-environment surfaces with and without a UVCCU. The reduction in bacterial colony counts with and without the UVCCU was measured by counting colony-forming units and calculating the log reduction values, and the UV radiation leakage outside the UVCCU was measured. Results: The use of the UVCCU led to a significant reduction in MRSA colony counts, even in shadowed areas that had previously been inadequately disinfected (with the UVCCU: 2.7 [2.7-2.8]; without the UVCCU: 0.6 [0.5-0.7]; p < 0.01). Additionally, the use of the UVCCU kept the UV radiation leakage to the surrounding environment within regulated limits. Conclusions: These findings suggest that a UVCCU can enhance the disinfection efficacy for multidrug-resistant organisms on healthcare environmental surfaces. The portability and ease of use of the UVCCU indicate its promise as an auxiliary device for UV-C disinfection in healthcare settings.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты