BACKGROUND

Effective disinfection of elastomeric impression materials is vital in prosthodontics to prevent cross-contamination without compromising dimensional accuracy. This study aims to evaluate three-dimensional changes in die stone models derived from three elastomeric materials after treatment with three disinfectants.

MATERIALS AND

METHODS

A 3D-printed master model was used to make 120 impressions with three elastomeric materials: Addition Silicone (Perfit Huge), Condensation Silicone (Zhermack Zetaplus), and Polyether (3M ESPE). Each material underwent four disinfection protocols: no disinfection (T1, control), immersion in 5.25% Sodium Hypochlorite (T2), 2% Glutaraldehyde (T3), and 2% Chlorhexidine (T4) for 10 minutes. Impressions were poured with Type IV dental stone and measured at the canine and molar reference points using a coordinate measuring machine (CMM).

RESULTS

Addition Silicone consistently showed the highest dimensional accuracy across all disinfectants. Polyether recorded the lowest accuracy, especially in the control group (T1). Among disinfectants, 2% Glutaraldehyde (T3) preserved the highest dimensional fidelity, followed by NaOCl and CHX. ANOVA and Bonferroni post-hoc analysis revealed statistically significant differences in the canine region for Addition Silicone (P = 0.044), while other comparisons were not statistically significant.

CONCLUSION

Disinfection does not adversely affect dimensional stability of elastomeric impression materials. In total, 2% Glutaraldehyde demonstrated superior preservation of accuracy, particularly with Addition Silicone. Polyether showed the most dimensional variation, suggesting its hydrophilic nature may compromise stability post-disinfection. Clinical implication suggests selecting Addition Silicone with Glutaraldehyde for optimal results.

Для цитирования: Bulla Chaitra S, Puranik Shivakumar N, Bung Santosh Kumar, Kabbin Ramya B, Kalyanrao Eklarkar Priyanka, Patil Sourabh S. Evaluation of Dimensional Changes in Stone Casts from Disinfected Elastomeric Impressions Using Coordinate Measuring Machine.. Journal of pharmacy & bioallied sciences. 2025. DOI: 10.4103/jpbs.jpbs_1194_25.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.