Sterile Instrument Storage in an Austere Environment: Are Sterile Peel Packaging and Cellulose Wrapping Equivalent?
Аннотация
BACKGROUND
Recommendations for optimal temperature and humidity for sterile instrument storage vary according to different sources. Furthermore, there are limited data comparing methods of packing smaller, lightweight, low-profile instruments. The purpose of this study was to compare sterile peel packaging and sterile cellulose wrapping for sterile instrument storage in an austere environment characterized by elevated temperature and humidity.
METHODS
Stainless steel screws were sterilized and stored in either sterile peel packaging, sterile cellulose wrapping, or no packaging. Four groups were evaluated. Group 1 consisted of four screws in a sterile peelpack envelope and served as a time-zero control. Group 2 consisted of two groups of five screws, each packaged with blue sterilization cellulose wrap. Group 3 consisted of two groups of five screws, each packaged in sterile peel-pack envelopes. Group 4 consisted of 10 non-sterile unpackaged screws, which served as controls. Screws from groups 2, 3, and 4 were then cultured for 6 and 12 weeks. Temperature and humidity values were recorded in the instrument storage area.
RESULTS
Average temperature was 21.3°C (SD 1.2°C; range 18.9°C-27.2°C) and average humidity was 51.7% (SD 3.9%; range 39%- 70%). Groups 1 (time-zero control) and 2 (sterile cellulose wrapping) demonstrated no growth. After 6 and 12 weeks, groups 3 (sterile peel packaging) and 4 (control) demonstrated bacterial growth.
CONCLUSION
The most common culture isolates were gram-positive rods and two common nosocomial Staphylococcius species. Sterile peel packaging was not found to be equivalent to sterile cellulose wrapping in austere environmental conditions.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.