MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2319/061623-421.1

Медицинская библиотека · The Angle orthodontist · 2024

Efficacy of an experimental gaseous ozone-based sterilization method for clear aligners.

Nicita Fabiana, Calapaj Massimo, Alibrandi Simona, Donato Luigi, Aquilio Emidio, D'Angelo Rosalia, Sidoti Antonina

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To assess effectiveness of an experimental sterilization method based on the exposure of an O3/O2 gas mixture directly inside the packaging for clear aligners.

MATERIALS AND

METHODS

Fifty samples consisting of pieces of polyethylene terephthalate glycol (PET-G) aligners were contaminated by manual handling and subsequently divided into different groups (n = 30 for exposure to O3/O2 gas at different times, n = 10 for positive control with 2% chlorhexidine digluconate, n = 10 for negative control). The measurement of optical densities (OD) of the initial and final microbial cultures was recorded for all groups. Kruskal-Wallis test was used for differences between groups while Wilcoxon test was used to compare initial and final OD values within groups. Statistical significance was set at P < .05.

RESULTS

Comparison within the groups showed statistically significant differences for exposure to the gaseous mixture (72 hours), for positive and negative controls. Other significant differences were found in the multiple comparisons between the application of gaseous ozone (48 hours and 72 hours) and the negative control.

CONCLUSIONS

The direct exposure of gaseous ozone on the aligners inside their packaging showed microbicidal capacity at 72 hours, which was equivalent to the positive control with immersion in chlorhexidine digluconate. This innovative sterilization procedure could be considered in the final manufacturing processes of clear aligners to eliminate the potentially pathogenic microorganisms that are deposited on surfaces of these orthodontic devices.

Для цитирования: Nicita Fabiana, Calapaj Massimo, Alibrandi Simona, Donato Luigi, Aquilio Emidio, D'Angelo Rosalia, Sidoti Antonina. Efficacy of an experimental gaseous ozone-based sterilization method for clear aligners.. The Angle orthodontist. 2024. DOI: 10.2319/061623-421.1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.