m+Medelevator.RU
← Поиск публикаций
Journal of contemporary brachytherapy · 2023

The Montreal split ring applicator: Towards highly adaptive gynecological brachytherapy using 3D-printed biocompatible patient-specific interstitial caps.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kamio Yuji, Roy Marie-Ève, Morgan Lori-Anne, Barkati Maroie, Beauchemin Marie-Claude, DeBlois François, Basaric Borko, Carrier Jean-François, Bedwani Stéphane

Аннотация

PURPOSE: The addition of interstitial (IS) needles to intra-cavitary (IC) brachytherapy applicators is associated with improved outcomes in locally advanced cervical cancers involving parametrial tumor extensions. The purpose of this work was to validate a clinical workflow involving 3D-printed caps for a commercial IC split ring applicator that enable using IS needle trajectories tailored to each treatment.

MATERIAL AND METHODS: A dedicated software module was developed in this work allowing users to design patient-specific IS caps without knowledge of computer-aided design (CAD) software. This software module was integrated to 3D Brachy, a commercial software developed by Adaptiiv Medical Technologies Inc. For validation of the workflow, CAD models of ground truth caps with five IS needle trajectories were designed with Fusion 360™, 3D-printed, assembled with a split ring applicator, and CT-scanned with radio-opaque markers. 3D Brachy was then applied to generate a replica based on trajectories reconstructed from the radio-opaque markers. A comparison between ground truth and replicated IS needle trajectories was done using intersection points with planes at the level of the cervix (z = 0 cm) and a representative needle depth (z = 3 cm).

RESULTS: Prototypes of interstitial caps 3D-printed in both BioMed Amber and BioMed Clear SLA resins were tested to be functional both pre- and post-sterilization for IS needles with obliquity angles ≤ 45°. Distance-to-agreement at z = 0 cm and 3 cm as well as deviations in pitch and yaw angles of the five IS needle trajectories were found to have mean values of 3.3 ±2.1 mm, 7.3 ±2.0 mm, 2.9° ±2.3°, and 7.0° ±7.0°, respectively.

CONCLUSIONS: The clinical workflow for image-guided adaptive cervical cancer brachytherapy using the Montreal split ring applicator was validated.