MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ortho.2026.101144

Медицинская библиотека · International orthodontics · 2026

Antimicrobial activity, bacterial adhesion, and surface morphology of TiO2 nanoparticle-coated orthodontic elastomeric ligatures: An in vitro study.

Baqandwan Saleh M, Albelasy Nehal F, Eldars Waleed, Tawfik Marwa A

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The objective of this study was to evaluate the antimicrobial activity, bacterial adhesion, and surface morphology of orthodontic elastomeric ligatures coated with titanium dioxide nanoparticles (TiO2 NPs) at different concentrations over 4 weeks.

MATERIAL AND

METHODS

TiO2 NPs were synthesized via hydrothermal synthesis and applied at 5% and 10% on elastomeric ligatures (Ormco®) using a sol-gel dip-coating method. In all, 720 ligatures were divided into control (uncoated), 5%, and 10% TiO2 NPs groups. The primary objectives were to assess antimicrobial activity against Streptococcus mutans via agar diffusion immediately after coating and after 48 hours, 2 weeks, and 4 weeks of immersion in artificial saliva at 37°C, and to quantify bacterial adhesion as CFU. The secondary objectives included evaluation of surface morphology and roughness using SEM. Statistical analysis was performed using two-way ANOVA with Bonferroni correction.

RESULTS

Both TiO2 NP coated groups showed significantly higher antibacterial activity and lower bacterial adhesion than controls (P<0.001). In the 10% group, inhibition zones decreased by 6.8mm (95% CI: 4.9-8.7) at 48 hours, 10.6mm (95% CI: 8.7-12.5) at 2 weeks, and 24.7mm (95% CI: 22.8-26.6) at 4 weeks; 5% group showed smaller reductions (8.3mm, 13.9mm, 21.5mm). Bacterial adhesion declined by 9933 CFU (95% CI: 9113-10,754) for 10% and 6477 CFU (95% CI: 5656-7297) for 5%. The 10% coating consistently had the strongest antibacterial effect and lowest CFUs, though efficacy decreased over time. SEM revealed increased surface roughness, especially in the 10% group.

CONCLUSIONS

TiO2 NPs coatings, particularly at 10%, enhance short-term antibacterial properties of orthodontic ligatures. However, the antimicrobial benefits decrease over time due to coating degradation and exposure to saliva. Higher nanoparticle concentrations increase surface roughness, which may affect long-term biofilm resistance. Optimizing nanoparticle dispersion and coating durability is essential for sustained clinical effectiveness.

Для цитирования: Baqandwan Saleh M, Albelasy Nehal F, Eldars Waleed, Tawfik Marwa A. Antimicrobial activity, bacterial adhesion, and surface morphology of TiO2 nanoparticle-coated orthodontic elastomeric ligatures: An in vitro study.. International orthodontics. 2026. DOI: 10.1016/j.ortho.2026.101144.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.