Use of n-Butyl-2-Cyanoacrylate for Fallopian Tube Embolization via Selective Catheterization in a Rabbit Model: Feasibility Study for Potential Nonsurgical Sterilization.

Stewart Jessica K, Hipolito Canario Diego A, Daso Gabrielle, Thapa Diwash, Montgomery Stephanie, Kohi Maureen

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To determine whether fallopian tube embolization with n-butyl-2-cyanoacrylate (nBCA) administered via a microcatheter in a rabbit model was technically feasible and resulted in short-term tubal occlusion.

MATERIALS AND

METHODS

In 10 female New Zealand white rabbits, the 2 cervices were cannulated using a 5-F catheter and hydrophilic guide wire transvaginally. Salpingography confirmed tubal patency bilaterally. A 2.4-F microcatheter was advanced to the distal fallopian tube, and nBCA/ethiodized oil was administered as the microcatheter was withdrawn to fill the length of the tube. A metallic coil was deployed prior to nBCA administration in half of the fallopian tubes. Rabbits were evaluated for tubal occlusion with salpingography at 1 month, followed by euthanasia and histopathologic analysis. Inflammation and fibrosis were graded from 0 (normal) to 3 (severe).

RESULTS

Fallopian tube embolization was technically successful in 17 (85%) of 20 fallopian tubes. Thirteen (76%) of 17 embolized fallopian tubes were occluded at 1 month on salpingography (nBCA only, 7/9; nBCA and coil, 6/8). On histopathologic analysis, direct or indirect evidence of occlusion was observed in 14 (82%) of 17 fallopian tubes. Mild or early fibrosis was observed in 65% of the tubes. The mean inflammation and fibrosis scores for the embolized tubes were 0.62 and 0.94, respectively.

CONCLUSIONS

This pilot study demonstrated that embolization of rabbit fallopian tubes using nBCA administered via a microcatheter is technically feasible and results in occlusion of most fallopian tubes in the short term with minimal inflammation. Investigation of efficacy in preventing pregnancy over the long term is warranted.

Для цитирования: Stewart Jessica K, Hipolito Canario Diego A, Daso Gabrielle, Thapa Diwash, Montgomery Stephanie, Kohi Maureen. Use of n-Butyl-2-Cyanoacrylate for Fallopian Tube Embolization via Selective Catheterization in a Rabbit Model: Feasibility Study for Potential Nonsurgical Sterilization.. Journal of vascular and interventional radiology : JVIR. 2022. DOI: 10.1016/j.jvir.2022.10.026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.