MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arth.2022.02.070

Медицинская библиотека · The Journal of arthroplasty · 2022

Do Ultraviolet Air Disinfection Units Reduce Contamination by Particulates in Total Knee Replacement Procedures?

Jones Hugh L, Braly Houston L, Parsley Brian S, Gonzalez Jasmine L, Ausborn Valerie A M, Noble Philip C

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Prosthetic joint infections have become the leading cause of joint replacement failure. The primary sources of contamination are skin flora and bacteria from airborne particles. Portable ultraviolet air disinfection units are used in the Operating Room (OR) to prevent contamination from airborne particles; however, their effectiveness is not proven. The purpose of this study was to compare the rate of contamination of sites with and without Ultraviolet (UV) air disinfection units during active surgeries.

METHODS

Sedimentation rates of viable particles were measured during 40 primary TKA procedures. Half of the procedures were performed with ultraviolet air disinfection units. Air-borne particles were collected on nitrocellulose membranes at 5 locations within the OR. After incubation, all microbial colonies were counted and the sedimentation rates were reported in CFUs/m2/hr. 10 additional trials were performed in an empty OR with no staff present.

RESULTS

The average contamination rate of all sites was 22 ± 1.1 CFUs/m2/hr in the empty OR vs. 21.3 ± 4.6 CFUs/m2/hr with UV units and 20.3 ± 4.9 CFUs/m2/hr without (P = .03, P = .03, P = .964). Viable contaminates were found in the sterile field in 25% of UV cases vs 45% non-UV. These differences were not statistically significant. There were differences found however, according to the number of staff in the room (6 vs 7 staff: P = .036, 6 vs 8 staff: P = .004).

CONCLUSION

There was no statistical difference in contamination rate with the usage or non-usage of UV units. These 40 cases shows that the largest variables affecting the contamination rate were the number of staff present and size of the OR.

Для цитирования: Jones Hugh L, Braly Houston L, Parsley Brian S, Gonzalez Jasmine L, Ausborn Valerie A M, Noble Philip C. Do Ultraviolet Air Disinfection Units Reduce Contamination by Particulates in Total Knee Replacement Procedures?. The Journal of arthroplasty. 2022. DOI: 10.1016/j.arth.2022.02.070.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.