m+Medelevator.RU
← Поиск публикаций
Scientific reports · 2025

Impact of various cleaning protocols on the physical and aesthetic properties of 3D-printed orthodontic aligners.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Šimunović Luka, Pečanić Paula, Marić Antun Jakob, Haramina Tatjana, Rakić Iva Šrut, Meštrović Senka

Аннотация

The surface similarity phenomenon describes how users apply maintenance habits from one material to another based on perceived similarities. Cleaning protocols for thermoformed aligners are often used for three-dimensional (3D) printed aligners, despite their different material properties. This study aimed to evaluate how such practices impact the physical and aesthetic properties of 3D-printed aligners. A total of 84 polyurethane-based specimens were fabricated using direct light processing. They were divided into three groups: brushing only, brushing with toothpaste, and immersion in an alkaline solution (Corega). Each protocol simulated two weeks of daily cleaning. Surface roughness was assessed via profilometry and AFM, hardness via the Ball Indentation Method, and color change via VITA Easyshade before and after cleaning. Water absorption was measured daily over 14 days during immersion in either Corega or saline. Statistical analyses included Wilcoxon signed-rank tests, paired t-tests, one-way ANOVA with LSD post-hoc tests, and Kruskal-Wallis tests with post-hoc Dunn test. Brushing with toothpaste caused the greatest increase in surface roughness (ΔSa = 37.45 nm), followed by brushing alone (ΔSa = 10.55 nm); Corega slightly reduced roughness (ΔSa = -4.86 nm). Surface hardness increased after brushing but decreased with Corega (p < 0.05). No significant ΔE color differences were found, though "b" values decreased with brushing (p = 0.012). Water absorption stabilized at 8.47% in saline, while Corega immersion led to peak absorption on day 8 before degradation (p < 0.001). Cleaning methods designed for thermoformed aligners can alter surface properties and degrade 3D-printed aligners. Tailored cleaning protocols are essential to preserve their integrity and functionality.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты