MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/jpbs.jpbs_315_21

Медицинская библиотека · Journal of pharmacy & bioallied sciences · 2021

Assessment of Effect of Different Sterilization Agents on Dimensional Accuracy of Different Impression Materials in Implant Prosthesis - An In vitro Study.

Kavita Kumari, Reddy K R Parameshwar, Reddy K R Maheshwar, Kumar Swatantra, Pandey Gyanendra, Singh Revati

СтатьяПеревод в очереди

Аннотация

AIM: Sterilization of impression materials is of paramount importance. The present study was conducted to compare the effect of different disinfectants on dimensional accuracy of elastomeric impression materials used for implant prosthesis and other routine treatments.

MATERIALS AND

METHODS

The present study was conducted with polyvinyl siloxane (PVS) (regular body), PVS (medium body), PVS (heavy body), and polyether (medium body) impression materials. Glutaraldehyde (2%) and sodium hypochlorite (NaOCl, 0.525%) were the disinfectant solutions employed in the study. After 16 h, the specimens were measured under Leica WILD stereomicroscope and dimensions were compared with master die.

RESULTS

The dimensional change in the Controls, 2% glutaraldehyde (Group I), and 0.525% NaOCl (Group II) was non significant where as Group III and Group IV showed statistically significant difference (P < 0.05). Results also showed significantly higher tear strength (newton/millimeter) in Control group followed by Group I and Group II.

CONCLUSION

PVS (heavy body) was found to be most stable, and polyether was seen to be stable of all the impression materials.

Для цитирования: Kavita Kumari, Reddy K R Parameshwar, Reddy K R Maheshwar, Kumar Swatantra, Pandey Gyanendra, Singh Revati. Assessment of Effect of Different Sterilization Agents on Dimensional Accuracy of Different Impression Materials in Implant Prosthesis - An In vitro Study.. Journal of pharmacy & bioallied sciences. 2021. DOI: 10.4103/jpbs.jpbs_315_21.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.