Water research · 2021

Understanding adsorption and biodegradation in granular activated carbon for drinking water treatment: A critical review.

СтатьяОбзорНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yuan Jie, Passeport Elodie, Hofmann Ron

Аннотация

Drinking water treatment plants use granular activated carbon (GAC) to adsorb and remove trace organics, but the GAC has a limited lifetime in terms of adsorptive capacity and needs to be replaced before it is exhausted. Biological degradation of target contaminants can also occur in GAC filters, which might allow the GAC to remain in service longer than expected. However, GAC biofiltration remains poorly understood and unpredictable. To increase the understanding of adsorption and biodegradation in GAC, previous studies have conducted parallel column tests that use one column of GAC (potentially biologically active) to assess overall removal via both adsorption and biodegradation, and one column with either sterilized GAC or biological non-adsorbing media to assess adsorption or biodegradation alone. Mathematical models have also been established to give insight into the adsorption and biodegradation processes in GAC. In this review, the experimental and modeling approaches and results used to distinguish between the role of adsorption and biodegradation were summarized and critically discussed. We identified several limitations: (1) using biological non-adsorbing media in column tests might lead to non-representative extents of biodegradation; (2) sterilization methods may not effectively inhibit biological activity and may affect adsorption; (3) using virgin GAC coated with biofilm could overestimate adsorption; (4) potential biofilm detachment during column experiments could lead to biased results; (5) the parallel column test approach itself is not universally applicable; (6) competitive adsorption was neglected by previous models; (7) model formulations were based on virgin GAC only. To overcome these limitations, we proposed four new approaches: the use of gamma irradiation for sterilization, a novel minicolumn test, compound-specific isotope analysis to decipher the role of adsorption and biodegradation in situ, and a new model to simulate trace organic adsorption and biodegradation in a GAC filter .

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты