Shen Xianyue, Qin Yanguo, Zuo Jianlin, Liu Tong, Xiao Jianlin
Аннотация
BACKGROUND: The inadvertent contamination of anterior cruciate ligament (ACL) grafts can occur if they are accidentally dropped on the floor during ACL reconstruction. There has been no meta-analysis conducted to compare the sterilization efficiency of the different disinfectants used on dropped ACL grafts.
PURPOSE: To compare the sterilization efficiency of 3 disinfectants to decontaminate ACL grafts as necessary.
STUDY DESIGN: Systematic review.
METHODS: A systematic literature review was performed using the MEDLINE, Embase, and Cochrane Library databases. All studies reporting the management of dropped or contaminated grafts were considered for this meta-analysis.
RESULTS: A total of 7 studies meeting inclusion criteria were identified from a literature search. The pooled results of this meta-analysis indicated that the rate of positive cultures of ACL grafts dropped on the operating room floor was 44.9% and that the commonly contaminated microbes were staphylococci and bacilli. The meta-analysis results indicated that the sterilization efficiency of a 4% chlorhexidine solution was superior to an antibiotic solution (odds ratio [OR], 0.17 [95% CI, 0.05-0.57]; P = .004) and a 10% povidone-iodine solution (OR, 0.04 [95% CI, 0.01-0.20]; P < .0001). Further, the antibiotic solution was superior to the 10% povidone-iodine solution (OR, 0.20 [95% CI, 0.07-0.55]; P = .002).
CONCLUSION: The results of our meta-analysis demonstrated that staphylococci and bacilli were the most common contaminants on dropped ACL grafts and that decontamination using a 4% chlorhexidine solution more reliably disinfected ACL grafts. This information can help to guide surgeons as regards appropriate remedial measures.
PURPOSE: To compare the sterilization efficiency of 3 disinfectants to decontaminate ACL grafts as necessary.
STUDY DESIGN: Systematic review.
METHODS: A systematic literature review was performed using the MEDLINE, Embase, and Cochrane Library databases. All studies reporting the management of dropped or contaminated grafts were considered for this meta-analysis.
RESULTS: A total of 7 studies meeting inclusion criteria were identified from a literature search. The pooled results of this meta-analysis indicated that the rate of positive cultures of ACL grafts dropped on the operating room floor was 44.9% and that the commonly contaminated microbes were staphylococci and bacilli. The meta-analysis results indicated that the sterilization efficiency of a 4% chlorhexidine solution was superior to an antibiotic solution (odds ratio [OR], 0.17 [95% CI, 0.05-0.57]; P = .004) and a 10% povidone-iodine solution (OR, 0.04 [95% CI, 0.01-0.20]; P < .0001). Further, the antibiotic solution was superior to the 10% povidone-iodine solution (OR, 0.20 [95% CI, 0.07-0.55]; P = .002).
CONCLUSION: The results of our meta-analysis demonstrated that staphylococci and bacilli were the most common contaminants on dropped ACL grafts and that decontamination using a 4% chlorhexidine solution more reliably disinfected ACL grafts. This information can help to guide surgeons as regards appropriate remedial measures.