Mechanical Behaviour of Orthodontic Auxiliary Photopolymerisable Resins in Simulated Oral Conditions: An In Vitro Study.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Favero Riccardo, Zanetti Tommaso, Tosco Vincenzo, Monterubbianesi Riccardo, Volpato Andrea
Аннотация
BACKGROUND: The widespread adoption of clear aligners in orthodontic practice has driven the development of biomechanical devices to improve treatment efficiency. The mechanical properties of these materials play a critical role in determining their clinical performance and efficacy. This study investigates the Young's modulus of Clear-Blokker® (Scheu Dental), a photopolymerisable resin used for the attachment of clear aligner, and evaluates its mechanical behaviour under different curing times (5 s and 10 s) and environmental conditions (dry storage and immersion in artificial saliva at 37 °C).
METHODS: Forty-eight cylindrical specimens were prepared and subjected to quasistatic compression tests after 14 days. A multi-factorial analysis of variance (ANOVA) at a significance level of 5% was performed to compare the variances.
RESULTS: The results showed that samples immersed in artificial saliva had significantly reduced Young's moduli compared to samples stored in dry conditions (p = 0.0213), while no significant difference was observed between curing times.
CONCLUSIONS: The results suggest that Clear-Blokker® has mechanical properties comparable to those of clear aligner materials, making it suitable as a biomechanical aid for orthodontic treatment. However, further clinical studies are required to confirm its long-term efficacy in the oral environment.
METHODS: Forty-eight cylindrical specimens were prepared and subjected to quasistatic compression tests after 14 days. A multi-factorial analysis of variance (ANOVA) at a significance level of 5% was performed to compare the variances.
RESULTS: The results showed that samples immersed in artificial saliva had significantly reduced Young's moduli compared to samples stored in dry conditions (p = 0.0213), while no significant difference was observed between curing times.
CONCLUSIONS: The results suggest that Clear-Blokker® has mechanical properties comparable to those of clear aligner materials, making it suitable as a biomechanical aid for orthodontic treatment. However, further clinical studies are required to confirm its long-term efficacy in the oral environment.